Count Rate Mode With Dose Rate Display - Thermo Scientific RadEye PRD-ER Operating Instructions Manual

Alarming personal radiation detector
Table of Contents

Advertisement

rd
- 3
click:
After 10 seconds or after 4
rate indication is activated again.
st
1
click
3.2.1.2
In this mode the measurement value of the dose rate is displayed
together with the bar graph of the cps value. The count rate alarm
thresholds are active. That is the alarming has a quick alarm re-
sponse, while the calculating of the dose rate for low count rates
takes place over a longer time. (see chapter 3.2.2).
This mode is for rapid finding of radioactive sources while
displaying true dose rate values. A press on the hot key (arrow
up) results directly to the display of the accumulated dose
respectively the mean- and max value.
This mode can be activated or deactivated alternatively to the
Count Rate Mode (3.2.1) via PC-Software only.
3-6
the mean value and max value of the measured
count rate (cps), together with the time
indicated since the last reset.
th
click standard display with count
nd
2
click

Count Rate Mode with Dose Rate Display

DB-066 E
rd
3
click
RadEye PRD-ER
Iw/Tr/Ff 06.07.2015