Commissioning

4
Commissioning
4.1

Connection

This section contains information on how to commission the IDENTControl
Compact.
The example commissioning procedure described relates to the IDENTControl
Compact with Ethernet interface.
Caution!
Uncontrollable triggered processes
The plant where the device is installed may be damaged.
Before commissioning, make sure that all processes run in a controlled manner.
Warning!
Incorrect electrical connection
Damage to the device or system caused by incorrect electrical connection
Check all connections in the plant before commissioning the device.
When the supply voltage is connected, the PWR/ERR LED on the device lights up
green. If the LED on the device doesn't light up, either the power supply is
connected incorrectly or there is a device fault.
4.2

Setting the IP address

The IP address of the IDENTControl Compact is preset to 169.254.10.12. The
way in which the IP address is modified depends on if you are using a DHCP
server.
If you are not using a DHCP server, the IP address is manually assigned: Either
select the IP address using the rotary switch or start the device with the preset IP
address and specify the new IP address on the device website.
If you are using a DHCP server, the server assigns the IP address to the
IDENTControl Compact.
Note!
We recommend using a fixed preset IP address in order to avoid system
malfunctions.
Note!
The rotary switch used to select the device address is located on the underside of
the IDENTControl Compact. This rotary switch is no longer accessible once the
IDENTControl Compact is installed.