Pepperl+Fuchs IDENTControl IC-KP2 Series Quick Start Manual page 15

Control interfaces
Table of Contents

Advertisement

IC-KP2-*
Commissioning
Setting the IP address using the rotary switch
1. Select an IP address. Insert leading zeros so that all the numbers have three
digits and then remove the periods. Example: Write the IP address
172.16.10.15 like this: 172016010015.
2. Set the rotary switch to position "F".
3. Restart the IDENTControl Compact by resetting the power supply.
The "ADDR STATE" LED will flash green.
4. Select the first digit of the IP address using the rotary switch and wait until the
"ADDR STATE" LED permanently lights up.
5. Select the next digit using the rotary switch and wait until the "ADDR STATE"
LED permanently lights up.
6. Repeat this procedure until you have entered all the digits of the IP address.
7. Set the rotary switch to position "0".
8. Configure other network settings in the Network window on the device
website ().
Entering the IP address on the website
The IP address of the PC connected to the IDENTControl Compact must come
from the address area 169.254.X.X.
1. Set the rotary switch to position "A".
2. Connect the IDENTControl Compact to a PC via the Ethernet interface.
3. Restart the IDENTControl Compact by resetting the power supply.
4. Open the IDENTControl Compact website by entering the preset IP address
(169.254.10.12) in a browser.
5. Open the Network window. Enter the user name and password (default on
delivery: "identcontrol"). Enter the new IP address and configure other
settings as required.
6. Set the rotary switch to position "0".
7. Click save.
The IDENTControl Compact restarts with the new IP address.
For a description of other web functions .
Obtaining an IP address from the DHCP server
Set the rotary switch to "D" and start the device.
The IDENTControl Compact retrieves the network settings from the DHCP
server during startup: IP address, subnet mask and gateway address.