IC-KP2-*
Installation
3.2.4
CC-Link interface
The control interface IC-KP2-2HB18-2V1 occupies 4 sations according to CC-
Link.
CC-Link IN: M12 connector, A-coded
Pin assignment
2
CC-Link OUT: M12 socket, A-coded
Pin assignment
5
4
Caution!
Damage to the control interface and connected slaves
It is possible to switch the power socket and the CC-Link IN socket as well as the
channel and the CC-Link OUT connector. If the power supply is connected to the
CC-Link IN socket, the control interface IC-KP2-2HB18-2V1 and all other slaves
connected to CC-Link OUT could be damaged.
Terminal resistor
Pin assignment
2
Pin
1
1
2
3
4
4
3
Pin
1
1
2
3
2
4
3
5
Pin
1
1
2
3
4
4
3
Signal
Description
SLD
Shield
DB (white)
Data B
DG (yellow)
Grounding
DA (blue)
Data A
Signal
Description
SLD
Shield
DB (white)
Data B
DG (yellow)
Grounding
DA (blue)
Data A
NC
not connected
Signal
Description
NC
not connected
DB
Data B
NC
not connected
DA
Data A