Datalogger Program - Xylem Ai1 Product Manual

Hide thumbs Also See for Ai1:
Table of Contents

Advertisement

Battery
bAt
Temperature deGC
The power consumption of the display depends on illuminated elements, from 4mA with all off to 18mA with all on,
typically 13mA (at 5V).
The wiring is different for each display type, summarised in the table below
Function
Ai1 Terminal
Power
Vx1
Ground
GND
Data
TX/C1/C2*
Switch Press
A1
Switch Excite
PSW
USB D+
USB D-
USB 5V
* Usage of TX, C1 or C2 depends on program function

10. Datalogger Program

All stations are pre-programmed to suit the ordered configuration options, with a user editable CRBasic program.
The CRBasic files are supplied as Open-Source Software, allowing viewing, and editing of the code. CRBasic files
may be edited in a basic text editor such as Notepad or using the feature rich CRBasic editor
(www.campbellsci.com/crbasiceditor
User Program
Calls Ai1OSn.nn.cr300
Available to add any
custom user
programming.
If a module is missing, the wrong version used, or the user program contains an error, a compile error will be
generated. CRBasic editing is an advanced topic and is not included in standard product support. Custom
engineering may be performed with a support agreement. As the software is in rapid development, the OS features
will continue to be enhanced. The testing with a new OS library file is up to the end user to ensure compatibility
with the Ai1 hardware configuration provided. Backward compatibility is not guaranteed. All library files are open-
source and may be user edited if desired.
It is possible to compile the include programs into a single file, eliminating Ai1OS
code related to options that are not used (improves readability, simplifies finding
bugs and reduces the time to transfer files). Select Conditional Compile, Include
Files and Save from the Compile pulldown menu, and specify the filename (which
must be different to the current filenames). It is also possible to compress the
program (remove comments and whitespace) for low-speed communications links.
Select Create Compressed File from the Edit menu. This is the default setting.
22
The CRBasic is a licenced program, refer to support for pricing. CRBasic is available for free as an inclusion with PC400 which only needs an email address for registration, available:
https://www.campbellsci.com/pc400
Page | 62
TSS
Internal Display
External Display
Red
Brown
Black
Black
White
White
Switch black
Blue
Switch black
Grey
22
). The program may be downloaded directly from the Ai1.
Ai1OSn.nn.cr300
Standard for all Ai1's, where n.nn denotes version.
Provides all the system functions.
Supplied from the factory.
Updated for new features and bug fixes.
YSIP Include File
Precompiled, encrypted, not user accessible.
Required for any YSI sensors using RS485 interface.
tSS
External Display + USB
Brown
Blue
Grey
Yellow
Pink
White
Green
Red

Advertisement