high precision 24-bit ADC, with 0 to 6V signals, or 4-20mA signals being measured through a configurable resistor
network. Analog inputs are fitted with surge protection.
Intern (JST) Terminal
1: Red
SW12 or BAT
2: Black
GND
3: Yellow
SDI12 (C1 or C2)
4: Green
Not used
5: Blue
Not used
(uses Digital main board header)

Voltage to Current (4-20mA)

Converts 0 to 2.5V to 4-20mA output signal.
Intern (JST) Terminal
1: Red
BAT
2: Black
GND
3: Yellow
User defined
4: Green
User defined
5: Blue
0-2.5V (Vx1)
(uses Analog main board header)

4-20mA Current Output module (Modbus RTU)

Two varieties are available, a 1-channel and 4-channel models, providing independent 4-20mA output signals,
controlled using Modbus RTU commands. (FUTURE)

RS232 to HART (4-20mA) Output module

Provides a HART compatible 4-20mA output signal, controlled using the dataloggers RS232 port. A CRBasic library is
provided for serial communications to the interface. (FUTURE)

RS232 to UART

Converts datalogger RS232 port to TTL UART.
Intern (JST) Terminal
1: Red
SW12V
2: Black
GND
3: Yellow
RS232 RX
4: Green
RS232 TX
5: Blue
5V (Vx)
(uses Digital main board header)

RS232 to RS485

Converts datalogger RS232 port to RS485, with 3-stage surge protection for increased protection .
Intern (JST) Terminal
1: Red
BAT/SW12V
2: Black
GND
3: Yellow
RS232 RX
4: Green
RS232 TX
5: Blue
5V (Vx)
(uses Digital main board header)

3-Stage Surge Protection (4-wire)

Provides 3-stage surge protection to incoming wires
Intern (JST) Terminal
1: Red
User defined
2: Black
GND
3: Yellow
User defined
4: Green
User defined
5: Blue
User defined
(uses Digital main board header)
Page | 26
Connection
External (M12) Sensor
→
1: Brown
→
4: Black
X
2: White
3: Blue
5: Grey
Connection
External (M12) Sensor
→
1: Brown
→
4: Black
→
2: White
→
5: Grey
X
3: Blue
Connection
External (M12) Sensor
→
1: Brown
→
4: Black
X
2: White
X
5: Grey
→
3: Blue
Connection
External (M12) Sensor
→
1: Brown
→
4: Black
X
2: White
X
5: Grey
X
3: Blue
Connection
External (M12) Sensor
→
1: Brown
→
4: Black
→
2: White
→
5: Grey
→
3: Blue
Sensor Power
Ground
Analog In 1
Analog In 2
Analog In 3
Power
Ground
User defined
User defined
I
(4-20mA)
out
Sensor Power
Ground
UART RX
UART TX
5V (Vx)
Sensor Power
Ground
Not used
RS485_A (-)
RS485_B (+)
Protection
1-Stage (TVS)
Earth lug
1-Stage (TVS)
1-Stage (TVS)
1-Stage (TVS)
Protection
1-Stage (TVS)
Earth lug
1-Stage (TVS)
1-Stage (TVS)
1-Stage (TVS)
Protection
1-Stage (TVS)
Earth lug
1-Stage (TVS)
1-Stage (TVS)
1-Stage (TVS)
Protection
3-Stage
Earth lug
3-Stage
3-Stage
3-Stage
Protection
3-Stage
Earth lug
3-Stage
3-Stage
3-Stage

Advertisement