Xylem ecocirc XL Instruction Manual

Xylem ecocirc XL Instruction Manual

Single/three phase pump
Table of Contents

Advertisement

INSTRUCTION MANUAL
P2002548 Rev E
Single Phase Pump
Three Phase Pump
®
ecocirc
XL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ecocirc XL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Xylem ecocirc XL

  • Page 1 INSTRUCTION MANUAL P2002548 Rev E Single Phase Pump Three Phase Pump ® ecocirc...
  • Page 3: Table Of Contents

    Table of Contents Table of Contents 1 Introduction and Safety................................3 1.1 Introduction....................................3 1.2 Safety terminology and symbols..............................3 1.3 Protecting the environment................................3 1.4 Spare parts....................................3 2 Transportation and Storage...............................3 2.1 Inspect the delivery..................................3 2.2 Transportation guidelines................................3 2.3 Storage guidelines..................................3 3 Product Description...................................3 3.1 Pump design....................................
  • Page 4 Table of Contents 8.6 Faults, causes, and remedies..............................14 9 Other Relevant Documentation or Manuals..........................15 9.1 Embedded Software and Driver Software License Agreement..................15 10 Product warranty................................... 15 ecocirc ® XL INSTRUCTION MANUAL...
  • Page 5: Introduction And Safety

    1 Introduction and Safety Exceptional sites 1 Introduction and Safety CAUTION: Radiation Hazard Do NOT send the product to Xylem if it has been exposed to nuclear radiation, unless Xylem has been informed and ap- 1.1 Introduction propriate actions have been agreed upon.
  • Page 6: Product Description

    3 Product Description 3.2 Product nomenclature 3.1 Pump design Example: ecocirc XL N 15–75 • The ecocirc XL is a large wet rotor pump with energy efficient, elec- tronically commutated permanent magnet motor. ecocirc XL high efficiency pump series • The pump is designed for systems with variable flow rates to opti- Pump type: mize pump operation thus reducing energy consumption.
  • Page 7: Sound Pressure Levels

    4 Installation Feature Description CSA certification NSF/ANSI-372 compliant (stainless steel body parts) UL/cUL Listed UL 778 - Motor operated water pump UL1004 - Motors UL listing UL 60730 - Inverters UL listing BTL Certification BacNet Smart Actuator (B-SA) 3.4 Sound pressure levels Nominal pump HP Sound pressure level (approxi- mate values)
  • Page 8: De-Rating Table

    4 Installation The electrical control panel checklist NOTICE: • Ensure that the suction pressure is never below the values specified NOTICE: above, as this could cause cavitation and damage the pump. The electrical supply must match the electrical rating of the pump. Im- •...
  • Page 9: Change The Position Of The Motor Housing

    4 Installation 1. Loosen the four hex-head screws (2) that fix the motor to the pump 4.7 Change the position of the motor housing (4) using the T-handle allen wrench described. housing 2. Rotate the motor (1) in 90° steps to the desired position. 3.
  • Page 10 The communications and control circuits within the ecocirc XL drive are floating from ground and are classified as SELV. They must be con- nected only to other SELV circuits in a manner which main- tains all the circuits within the SELV limits and prevents ground loops.
  • Page 11: I/O Connections

    5 System Description 5. Setting buttons 4.8.2 I/O connections 6. Numeric display 7. Power indicator 1. Open the terminal box cover removing the screws (5). Refer to fig- 8. Status / Fault indicator ures 2 & 3 on page 7. Use control screwdriver described under sec- 9.
  • Page 12: Temperature Dependent Control Modes

    5 System Description 5.2.2 Temperature dependent control modes SPEED For details refer to the electronic drive manual on www.bellgos- sett.com. 5.2.2.1 ∆p-T control This function adjusts the nominal differential pressure set point accord- ing to the temperature of the pumped media. SETPOINT For details refer to the electronic drive manual on www.bellgos- sett.com...
  • Page 13: External Sensors

    6 System Setup and Operation 8 and Figure 7: Connection diagram for three phase models on page 8 NOTICE: for location. If there is a fault, the relay contact closes to display a red The differential sensor cables shall not exceed 65 ft. status light and the error code on the user interface display.
  • Page 14: Configure The Pump Settings

    6 System Setup and Operation NOTICE: • Never operate the pump with discharge valve closed for longer than a few seconds. • Do not expose an idle pump to freezing conditions. Drain all liquid mode mode that is inside the pump. Failure to do so can cause liquid to freeze and damage the pump.
  • Page 15: Automatic Air Venting Procedure

    7 Maintenance – Switch on power to supply the pump. The second pump is configured automatically by the lead pump. Refer – Close the start/stop contact by jumpering terminals 11 and 12 to Electronic Drive Manual for further details. on single phase pumps and terminals 13 and 14 for three phase pumps, or through a remote dry contact..
  • Page 16: Fault And Error Codes (Red Led)

    8 Troubleshooting Operating LEDs / Dis- Cause Solution 8.5 Alarm codes (Orange LED) play Remote Off Remote communica- If the communication Alarm code Cause Solution tion is deactivated does not work, check Fluid sensor malfunction Switch off the pump for 5 the connection and the minutes and then power configuration parame-...
  • Page 17: Other Relevant Documentation Or Manuals

    9 Other Relevant Documentation or Manuals Changes or modifications not expressly approved by the manufacturer Cause Solution responsible for compliance could void the user’s authority to operate Tripped circuit breaker or Reset power supply circuit breaker and the equipment. ground-fault protection determine cause for overload.
  • Page 18 10 Product warranty date code, whichever shall occur first, unless a longer period is provid- ed by law or is specified in the product documentation (the “Warran- ty”). Except as otherwise required by law, Seller shall, at its option and at no cost to Buyer, either repair or replace any product which fails to con- form with the Warranty provided Buyer gives written notice to Seller of any defects in material or workmanship within ten (10) days of the date...
  • Page 20 Xylem also provides a leading portfolio of smart metering, network technologies and advanced analytics solutions for water, electric and gas utilities. In more...