Summary of Contents for Xylem GSP0311

  • Page 1 INSTRUCTION MANUAL Sump and Effluent Pump...
  • Page 3: Table Of Contents

    Table of Contents Table of Contents 1 Introduction and Safety......................2 1.1 Introduction.......................... 2 1.2 Safety............................. 2 1.2.1 Safety terminology and symbols.................2 1.2.2 User safety........................3 1.3 Protecting the environment....................4 2 Transportation and Storage...................... 5 2.1 Inspect the delivery......................5 2.1.1 Inspect the package..................... 5 2.1.2 Inspect the unit......................5 3 Product Description........................6 3.1 General description......................
  • Page 4: Introduction And Safety

    This includes any modification to the equipment or use of parts not provided by Xylem. If there is a question regarding the intended use of the equipment, please contact a Xylem representative before proceeding.
  • Page 5: User Safety

    1 Introduction and Safety Hazard level Indication A hazardous situation which, if not avoided, could result WARNING: in death or serious injury A hazardous situation which, if not avoided, could result CAUTION: in minor or moderate injury Notices are used when there is a risk of equipment NOTICE: damage or decreased performance, but not personal injury.
  • Page 6: Protecting The Environment

    • Clean-up of spills Exceptional sites CAUTION: Radiation Hazard Do NOT send the product to Xylem if it has been exposed to nuclear radiation, unless Xylem has been informed and appropriate actions have been agreed upon. Recycling guidelines Always follow local laws and regulations regarding recycling.
  • Page 7: Transportation And Storage

    2 Transportation and Storage 2 Transportation and Storage 2.1 Inspect the delivery 2.1.1 Inspect the package 1. Inspect the package for damaged or missing items upon delivery. 2. Note any damaged or missing items on the receipt and freight bill. 3.
  • Page 8: Product Description

    3.2 Operational specifications Limitations Model Discharge size Capacities Maximum head Solids handling Maximum temperature (continuous operation) GSP0311 11/2” NPT to 43 GPM to 22’ TDH 1/2” spherical 104°F (40°C) GSP0511 11/2” NPT to 71GPM to 24’ TDH 1/2” spherical 104°F (40°C)
  • Page 9 3 Product Description Warning device alarms Table 1: Model information Alarm Agency NEMA Float Float Power Audible Primary Hertz Voltage to Battery Additional order no. listing rating switch switch cord alarm power float backup features included length length type/db at switch alarm 10’...
  • Page 10 3 Product Description NOTICE: Failure to install a warning device or a suitable back up sump pump may lead to property damage when there is a loss of pump function in the main sump pump. Sump and Effluent Pump INSTRUCTION MANUAL...
  • Page 11: Installation

    4 Installation 4 Installation 4.1 Preinstallation WARNING: • Disconnect and lock out electrical power before installing or servicing the unit to prevent unexpected start-up. • Do NOT install this pump in swimming pools or marine areas. • Risk of electric shock. This pump is supplied with a grounding conductor and grounding-type attachment plug.
  • Page 12: Piping Checklist

    4 Installation 4.1.2 Piping checklist Guideline Explanation Discharge pipe should be the same size as the pump. This insures optimum performance. Undersized pipe can dramatically reduce the flow and waste energy. 4.2 Typical installation Typical pump installation in sump; Tether float shown, float not needed on models with included float.
  • Page 13: Install The Pump

    4 Installation NOTICE: • Use only copper wire to the drive unit and the ground (earth) . The ground (earth) wire must be at least as thick as the wire to the drive unit. • Conductors should have color codes to make the maintenance easier. 4.4 Install the pump DO NOT place the pump directly on earth, gravel or debris.
  • Page 14: Operation

    5 Operation 5 Operation 5.1 Start the pump 1. Turn the power On at the breaker panel and/or the disconnect switch. 2. Fill the basin with water and observe the level of water where the pump turns On and Off. The pump should go On well before the water overflows the top of the sump. The pump should go Off before the water gets below the pump suction.
  • Page 15: Maintenance

    6 Maintenance 6 Maintenance 6.1 Maintenance guidelines • Check frequently for debris and/or build-up which can interfere with pump or float operation. • Test pump periodically throughout the seasons. 1. Fill sump with water. 2. Check for debris and proper switch operation. 3.
  • Page 16: Troubleshooting

    7 Troubleshooting 7 Troubleshooting 7.1 Operation troubleshooting Symptom Cause Remedy Motor not running Tripped thermal protector Check that all pump functions and components are operating correctly. Allow the unit to cool for 30 minutes. If the thermal protector does not reset and no other causation exists, replace the pump.
  • Page 17: Product Warranty

    8 Product warranty 8 Product warranty Commercial warranty Warranty. For goods sold to commercial buyers, Seller warrants the goods sold to Buyer hereunder (with the exception of membranes, seals, gaskets, elastomer materials, coatings and other "wear parts" or consumables all of which are not warranted except as otherwise provided in the quotation or sales form) will be (i) be built in accordance with the specifications referred to in the quotation or sales form, if such specifications are expressly made a part of this Agreement, and (ii) free from defects in material and...
  • Page 18 8 Product warranty Limited consumer warranty Warranty. For goods sold for personal, family or household purposes, Seller warrants the goods purchased hereunder (with the exception of membranes, seals, gaskets, elastomer materials, coatings and other "wear parts" or consumables all of which are not warranted except as otherwise provided in the quotation or sales form) will be free from defects in material and workmanship for a period of twenty-four (24) months from the date of installation or thirty (30) months from the product date code, whichever shall occur first,...
  • Page 19 8 Product warranty To make a warranty claim, check first with the dealer from whom you purchased the product or visit www.xyleminc.com for the name and location of the nearest dealer providing warranty service. Sump and Effluent Pump INSTRUCTION MANUAL...
  • Page 20 For more information on how Xylem can help you, go to xyleminc.com Xylem Inc. Visit our Web site for the latest version of this document...