2-9. Mode SW Unit Replacement
(Removal)
1.
Confirm that the unit is in the unloading complete
position.
2.
Remove the cleaner solenoid unit. (Refer to 2-8)
3.
Disconnect the connectors on the Mech. I/F
board.
4.
Remove the spring on the cleaner arm unit.
5.
Unscrew 3 screws A, and the Motor Bracket Unit.
(Fig.2-9-1)
6.
Unscrew the 2 screws B, and the Mode SW Unit.
(Installation)
1.
Install a new Mode SW Unit in the reverse steps
of the removal.
2.
The pin at the bottom of the Mode SW should be
put into the hole of the Main Cam Gear. (Fig.2-9-1
and 2-9-2)
Fig.2-9-1
MECH-32