Cpld Version Upgrade Method (Altera) - Panasonic DVCPRO HD EX AJ-HD1200AP Service Manual

Hide thumbs Also See for DVCPRO HD EX AJ-HD1200AP:
Table of Contents

Advertisement

9-2-2. CPLD Version Upgrade Method (ALTERA)

< APRO, SDI, UDC CPLD IS's>
A. Preparation
ITEM
CPLD Writer
D-sub 25pin-25pin Cable
Version Upgrade
Software
File NAME
Personal Computer
B. Connection
1. Connect the D-sub Cable between CN201(for ALTERA) connector of the CPLD WRITER (VFK1590) and
Personal Computer (Printer port).
2. Connect the CPLD WRITER Cable (VFK1590P2) between the connector at the Board in the VTR as shown in
table 9-2A-4 and connector of the CPLD writer as shown in table 9-2A-3.
3. Turn on the VTR and Personal Computer (Windows mode).
C. Boot up the Ver. up Software and Ver. up Procedure
1. Select "start button" on the Windows Screen and then "Program" and then boot up the "MAX+plus II ***
programmer only" so that the following menu appears.
2. On main window, select tab "Assign" and then "Device" → "MAX700"(Device Family) →"AUTO".
3. Insert floppy disk (which is includes all files of the program software VVVSI*** as shown in table 9-2A-4) to
floppy drive.
VFK1590
VFK1590P2 (Standard Accessory of VFK1590)
Straight (Mail-Female), Length: Within 1m
MAX+plus II Software ver9.6 or over ver9.6
(Please access to
www.altera.com/support/software/download/sof-download_center.html)
jcf File (Included in "vvvsi xxxx" file).
(Copy all files of the VVVSI4283A, VVVSI4287B and VVVSI4241B which is
included " .jct " file to floppy disk)
WINDOWS 95® or 98®
Table 9-2B-1
Figure 9-2B-2
INF-31
REMARK

Advertisement

Table of Contents
loading