Power Supply Unit; Output Voltage Adjustment; Sys (System Control) Board; Battery Voltage Detect Adjustment - Panasonic DVCPRO HD EX AJ-HD1200AP Service Manual

Hide thumbs Also See for DVCPRO HD EX AJ-HD1200AP:
Table of Contents

Advertisement

1. POWER Supply Unit

1-1. Output Voltage Adjustment

BOARD
POWER 3
TP
TP1, TP14 [GND]
TP2, TP14 [GND]
ADJ.
VR2, VR3
TAPE
---
INPUT
EJECT
MODE
---
M. EQ
Digital Volt Meter
SPEC.
VR2 : 1.92V ± 0.05V
VR3 : 1.40V ± 0.05V
1.
Connect the Digital Volt Meter (+) to TP1 and (-)
to TP14, and adjust VR2 so that the voltage is in
the specification.
2.
Connect the Digital Volt Meter (+) to TP2 and (-)
to TP14, and adjust VR3 so that the voltage is in
the specification.
2. SYS (System Control)
2-1. Battery Voltage Detect
Adjustment
BOARD
VOUT/SYS
TP
DC IN (See Figure Below)
ADJ.
SERVICE MENU "H00"
TAPE
---
INPUT
EJECT
MODE
---
M. EQ
Digital Volt Meter
SPEC.
12.00V ± 0.02V
<Service Manu Setting>
H00: OTHER ADJUST -----
nd
1. Set the 2
bit of DIP SW1 on the VOUT/SYS
Board to the ON position.
2. Set the "LOCAL/MENU/REMOTE" switche on the
rigit upper side of the front panel to the MENU
position.
3. Supply a DC Power from DC Supply to the XLR 4
pin connector on the rear panel as shown in the
figure below.
4. Connect the Digital Volt Meter to the DC Power
Supply as shown in the figure below.
5. Adjust the voltage of the DC power Supply so that
the voltage is 12.00V ± 0.02V.
6. Open the Service Menu and select H00: OTHER
ADJUST (H21: UNDERCUT ADJ).
7. Continually pushing the MODE button until the
display is updated.
8. To return the main menu, press the PAGE and
MODE buttons together.
Board)
H21: UNDERCUT ADJ
9. Return the LOCAL/MENU/REMOTE switch to the
LOCAL position, and 2
"OFF" position.
<CAUTION>
1. Disconnect
adjustment with DC Power. Supply.
2. This adjustment should be performed after
completion of the Paragraph "1-1. Output Voltage
Adjustment".
Adjustment Point:
DC IN
(XLR 4P Connector)
AJ-HD1200A
2
1
4
3
Pin 4 : 12V
Pin 1 : GND
<Confirmation of Under Cut Operation>
1. After completion of the above adjustment, confirm
the "Under Cut Operation"
2.
Make
sure
AJ-YA120AG and AJ-YAD120AG are installed. If
not, install them according to the Operation
Instraction.
3.
Supply DC 12.00V from DC Power Supplier to the
XLR 4 pin connector and connect the digital volt
meter as shown in the above figire.
4.
Turn on the VTR power and insert a cassette tape,
and place the VTR in the STOP mode.
5.
Observe the VTR condition while decrease the
voltage at the XLR connector for 10.60V
6.
Confirm that the VTR changes to Auto Eject and then
Auto Off mode.
7.
If it does not, perform the adjustment steps 1 to 9