2-24. M Stopper Solenoid Unit
Replace & Adjustment
(Removal)
1.
Remove the connector P24 on the backside of the
Mech. I/F board.
2.
Remove the Pinch Solenoid Unit. (Refer to the
Pinch Solenoid Replacement procedure.)
3.
Remove the T Tension Base Unit. (Refer to the
T5 Arm Unit Replacement Procedure.)
4.
Remove the 4 screws A and B, and then the
solenoid. (Fig. 2-24-1)
(Installation)
1.
Install a new solenoid in the reverse steps of the
removal.
2.
The following position adjustment is required.
M Stopper Solenoid
Fig.2-24-1
(Adjustment)
1.
Place the reel in the L cassette position.
2.
Press the core of the solenoid to release the M
stopper.
3.
Loosen the screw A and adjust the solenoid
position so that the gap between the Mech.
Chassis and the M stopper is 1.1 to 1.3mm. (Fig.
2-24-2)
4.
Tighten the screw A after the adjustment
S Reel
MECH-41