4. RF/EQ Board

< Note >
After
replacing
the
paragraphs 4-1, 4-2, 4-3 and 4-4. "RF Level
Adjustments" before performing LISTA adjustment.

4-1. RF Level Adj. (HDLP)

BOARD
RF/EQ
TP
See Table Below
ADJ.
Service Menu
INPUT
----
MODE
STILL
TAPE
VFM3780KML (Color Bar)
M. EQ
Oscilloscope
SPEC.
A Max = 500mVp-p ± 50mV
<Service Menu Setting>
B00: RF ADJUST ---- B-1: HDLP PB ADJUST
1.
Open the service menu and select the "HDLP PB
ADJUST".
2.
Connect the oscilloscope to Measuring Point
(MP) and Trigger Point (TG) as shown in the table
below.
3.
Play
back
the
(VFM3780KML) in the STILL mode.
4.
Adjust each EVR so that the envelope maximum
level is in the specification.
5.
To save the EVR data, select B22 DEFAULT and
press the "Set Button", then the "SAVE" indication
appears, press the "SET Button" again.
B1: HDLP_PB ADJUSTMENT
Test Point
Adj. EVR
TP201
B01
PB MAG L1
(PB L13ch)
B02
PB MAG L3
TP202
B03
PB MAG R1
(PB R13ch)
B04
PB MAG R3
TP203
B05
PB MAG L2
(PB L24ch)
B06
PB MAG L4
TP204
B07
PB MAG R2
(PB R24ch)
B08
PB MAG R4
TP205
B09
RP MAG L1
(RP L12ch)
B10
RP MAG L2
MP
TG
Refer the measuring point (MP) and torigger point (TG)
in the above for each head.
cylinder
unit,
perform
HDLP
alignment
Trigger Point
TP1
(PB L13 HSW)
TP2
(PB R13 HSW)
TP3
(PB L24 HSW)
TP4
(PB R24 HSW)
TP5
(RP L12 HSW)
"A" (MAX)

4-2. RF Level Adj. (HDSP)

the
BOARD
RF/EQ
TP
See Table Below
ADJ.
Service Menu
INPUT
----
MODE
STILL
TAPE
VFM3580KM or KL (25M Color Bar)
M. EQ
Oscilloscope
SPEC.
"A" Max = 500mVp-p ± 50mV
"A" Max = 750mVp-p ± 50mV (TP205)
<Service Menu Setting>
B00: RF ADJUST ---- B-2 HDSP ADJUST
1.
Open the service menu and select the "HDSP PB
ADJUST".
2.
Connect the oscilloscope to Measuring Point
(MP) and Trigger Point (TG) as shown in the table
below.
3.
Play
(VFM3580KMor KL) in the STILL mode.
4.
Adjust each EVR so that the envelope maximum
level is in the specification.
5.
To save the EVR data, select B22 DEFAULT and
tape
press the "Set Button", then the "SAVE" indication
appears, press the "SET Button" again.
<Note>
Since the adjustment value of TP205 differs from
others.
B2: HDSP_PB ADJUSTMENT
Test Point
TP201
(PB L13ch)
TP202
(PB R13ch)
TP203
(PB L24ch)
TP204
(PB R24ch)
TP205
(TR L21ch)
ELE-4
(TP201, TP202, TP203, TP204)
back
the
25M
Adj. EVR
B01
PB MAG L1
B02
PB MAG L3
B03
PB MAG R1
B04
PB MAG R3
B05
PB MAG L2
B06
PB MAG L4
B07
PB MAG R2
B08
PB MAG R4
B09
TR MAG L2
B10
TR MAG L1
alignment
tape
Trigger Point
TP1
(PB L13 HSW)
TP2
(PB R13 HSW)
TP3
(PB L24 HSW)
TP4
(PB R24 HSW)
TP7
(TR L21 HSW)

Advertisement