6.4.4.4.3 ACR10R
Step 1:
Activate the meter display by
pressing any key. Then click the "Set"
button.
Step 3:
Enter the password "0001" and
confirm the entry by pressing the Enter
key.
Electrical Connection
There are 5 buttons on the meter's
front:
1. Enter key
2. Arrow to the right
3. Up arrow
4. SET button
5. FN key (no function)
Step 2:
Use the arrow keys to select
the "SETUP" menu item and confirm
your selection with the Enter key.
Step 4:
Select the menu item "Comm"
in the settings menu to change to the
communication settings.