Functional
Symbols
Spool types shown repre-
sent the highest proportion
of market requirements. For
other spool functions that may
be required, consult your
Eaton sales representative.
Solenoids identified to U.S.
standards
Functional symbols related to
solenoid identity "A" and/or
"B" according to NFPA/ANSI
standards, i.e. energizing
solenoid "A" gives flow P to
A, solenoid "B" gives flow P
to B (as applicable).
Port P
Port A
Solenoid
Solenoid
Port B
Port T
For
Spool
SolEnoid
typE
SolEnoid
B
All
A
except
"8"
A
"8" only
B
For valves with type "8"spools,
solenoid identity to U.S.
convention is the same as for
European convention.
Solenoids identified to
European standards
(specify "V" in model code)
Functional symbols related
to solenoid identity "A" and/
or "B" according to European
convention i.e. solenoid "A"
adjacent to "A" port, solenoid
"B" adjacent to "B" port of
valve.
Port P
Port A
Solenoid
Solenoid
A
B
Port B
Port T
• For differences in valve func-
tion, refer to Performance
Data page 11.
F build spools.
◊
4
Eaton Vickers Solenoid Operated Directional Valves Product Catalog V-VLDI-MC011-E September 2008
U.S. solenoid standard
Double solenoid valves,
two position, detented
A
A
B
B
A
A
B
S
S
. l o
. l o
B
B
S
. l o
B
P
P
T
T
S
S
P
. l o
. l o
A
A
S
. l o
B
P
T
S
. l o
A
Double solenoid valves,
spring centered
A
B
A
B
A
B
A
B
S
S
. l o
. l o
B
B
S
. l o
P
P
B
T
T
P
S
S
. l o
. l o
T
A
A
S
. l o
B
P
T
S
. l o
A
Transient condition only
s
The valve function schematics apply to both U.S. and European valves.
DG4V-3(S)-*N(V)
2
2
2
DG4V-3(S)-*C(V)
0
0
0
2
2
2
6
6
6
66
66
66
7
7
7
2 2
2 2
2 2
33
33
33
34
34
34
2 5
2 5
2 5
6 5
6 5
6 5
DG4V-3(S)-8C(V)
8
8
8
European solenoid standard
Double solenoid valves,
two position, detented
A
A
B
B
A
P
P
T
T
P
Sol. A
Sol. A
Sol. A
Sol. B
Sol. B
Double solenoid valves,
spring centered
A
B
P
T
Sol. A
Sol. B
Transient condition only
s
Single solenoid valves,
solenoid at port A end
B
A
A
A
B
B
A
B
T
S
. l o
A
Sol. B
Sol. B
Sol. B
P
P
T
T
P
Sol. B
P
T
S
. l o
A
DG4V-3(S)-*A(V)
0
0
0
2
2
2
22
22
22
22
24
24
24
24
DG4V-3(S)-*B/F(V)
0
0
0
2
2
2
6
6
6
6
66
66
66
66
7
7
7
2 2
2 2
2 2
33
33
33
33
34
34
34
34
5
1 2
5
1 2
5
1 2
5
1 6
5
1 6
5
1 6
DG4V-3(S)-8BL(V)
8
8
8
Single solenoid valves,
solenoid at port A end
B
A
A
B
B
A
T
P
P
T
T
P
Sol. B
Sol. A
Sol. A
Sol. A
Single solenoid valves,
solenoid at port B end
B
B
B
A
A
A
B
B
A
T
P
P
T
T
P
T
Sol. A
Sol. A
P
T
Sol. A
DG4V-3(S)-*AL(V)
0
0
0
2
2
2
22
22
24
24
DG4V-3(S)-*BL/FL(V)
0
0
0
2
2
2
6
6
66
66
7
7
7
2 2
2 2
2 2
33
33
34
34
2 5
2 5
2 5
6 5
6 5
6 5
DG4V-3(S)-8B(V)
8
8
8
Single solenoid valves,
solenoid at port B end
A
B
A
B
B
A
B
P
T
P
T
T
P
T
Sol. B
Sol. B
Sol. B
Sol. A
Need help?
Do you have a question about the VICKERS SystemStak and is the answer not in the manual?