The Octalarm always remains operational during the battery test.

11.7.5 Testing and changing the battery

Over time, the battery needs to be replaced. This is subject to wear and then no longer
functions optimally. When the indicator LED lights up, it is recommended to replace the
battery as soon as possible.
If you slide up the Octalarm-IP's operating
panel in relation to the bottom plate and
then completely remove it (see paragraph
11.3 Enclosure), you will see the battery on
the right, above the mounting for the
sensor.
First remove the small cable that connects
the battery to the Octalarm-IP. The battery
is attached to the alarm dialler's bottom
plate with industrial quality Velcro. You can
remove the battery by pulling it loose.
The replacement battery should be put in
the place where the old one was. Press the
new battery firmly so that the Velcro gets a
good grip on it. When inserting the
connector please note that it only fits into the chassis part in one way, so do not use too
much force as this may damage the cable mounting. If you are holding the connector in
the correct position it will slide into the chassis part with very little effort.