Der U msc haltpunkt wird über den Weg ( mm/i nc h) oder den Druc k (Bar/Psi/M Pa) eing estellt. D er Wert, den di e M asc hine z uers t err eic ht, l öst das Umschalten von (schnell) Sc hließ en auf (langsam) U mfor men aus.
Proceed to the following screens:
1.
•
•
See "Operating pressure and counter settings",
Section 4.
(Option) PFC only:
2.
See "Pre-set PID controller (PFC only)" in Section
4.
(Option) Label printer
•
•
•
See "UNIFLEX Label System" (Option) in Section
5.
Return to previous screen.
Set machine switch
For machines with this option, the crimping dies are closed at two dif-
ferent speeds:
•
(rapid) Closing
•
(slow) Forming
The switch point is set by the distance (mm/inch) or the pressure
(bar/psi/MPa). The value reached by the machine first will trigger the
switch from (rapid) closing to (slow) forming.
This setting has no effect in machines without this option.
Need help?
Do you have a question about the Control C.2 and is the answer not in the manual?
Questions and answers