Operation guide User manual Installation, Operation and PAHT C pumps PAHT C 2- 6.3 Maintenance Manual for Installation, Operation and Maintenance Manual PAHT C 2-6.3 pumps hpp.danfoss.com...
Operation guide | Installation, Operation and Maintenance Manual for PAHT C 2-6.3 pumps Validity This manual is valid for PAHT C pumps both non In case the pump delivered is ATEX certified, the ATEX and ATEX certified versions . An ATEX additional ATEX instruction must also be read .
Operation guide | Installation, Operation and Maintenance Manual for PAHT C 2-6.3 pumps Introduction General • Operation outside the Danfoss specifications The PAHT C pumps and pump units are manufac- requires a written approval from Danfoss tured by Danfoss A/S, and are sold and marketed High Pressure Pumps .
Operation guide | Installation, Operation and Maintenance Manual for PAHT C 2-6.3 pumps 1.3 Manufacturer and customer service Your local Danfoss pump distributor can be address: found on our homepage . Danfoss A/S 1.4 Country specific information High Pressure Pumps 1.4.1 United Kingdom...
Operation guide | Installation, Operation and Maintenance Manual for PAHT C 2-6.3 pumps • Do not try to lift the pump unit manually; most of the pumps weigh more than 20 kilos, see specific weight for the pump It is always the system builders´ responsibility in the appendix 1, Data sheet .
Operation guide | Installation, Operation and Maintenance Manual for PAHT C 2-6.3 pumps 3.7 Filtration (10µm absolute [β ≥ 5000]) 3.9 Air bubbles Requirements are specified in appendix 1, Data Large bubbles in a pressurised system can result sheet and appendix 2, Instruction .
Operation guide | Installation, Operation and Maintenance Manual for PAHT C 2-6.3 pumps Pumps which have a weight above 20 kilos (see Wrong lifting: appendix 1, Data sheet) must be handled by using lifting eyes and slings . When lifting the pump unit, one sling must be attached to the electric motor and one sling around the pump .
Operation guide | Installation, Operation and Maintenance Manual for PAHT C 2-6.3 pumps Installation and commissioning 5.1 Important dimensions 5.3 Fluid temperature Physical dimensions and connections of the Before start-up, the fluid and pump housing temperature must be within the specified pump unit are described in appendix 1, Data sheet .
Operation guide | Installation, Operation and Maintenance Manual for PAHT C 2-6.3 pumps 5.6 Pre mounting checklist, based on Danfoss preferred system designs Table 1: Check points when assembling and commissioning system Check points Comment OK ? See Arrival inspection, transpor- Ensure that the environmental conditions are safe .
Operation guide | Installation, Operation and Maintenance Manual for PAHT C 2-6.3 pumps 5.12 Ensure free flow • Check the temperature switch/controls . The Ensure free flow from relief valve (table 1, item high-pressure pump must stop if tempera- 5 .6, CP 8) . A blocked relief valve can cause ture is above specified set point .
Operation guide | Installation, Operation and Maintenance Manual for PAHT C 2-6.3 pumps Operation of motor pump unit Drop in flow and/or pressure – may indicate 6.1 General safety information wear on one or more parts inside the Before inspecting the pump unit, read the Safety pump .
Operation guide | Installation, Operation and Maintenance Manual for PAHT C 2-6.3 pumps Slowly unscrew and remove the bolts and gaskets from the inlet/outlet hoses or pipes, be careful about jets of water . Be aware that the system can be pressurized .
Operation guide | Installation, Operation and Maintenance Manual for PAHT C 2-6.3 pumps Troubleshooting and Electrical scrapping criteria hazard 8.1 General safety information 8.4 Electrical failure Before inspecting the pump unit, it is necessary If the wiring of the electric motor is incorrect or...
Page 16
Operation guide | Installation, Operation and Maintenance Manual for PAHT C 2-6.3 pumps 180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022...
Operation guide User manual Appendices for Installation, Operation PAHT C pumps PAHT C 2-6.3 and Maintenance Manual Appendices for Installation, Operation and Maintenance Manual PAHT C 2-6.3 pumps hpp.danfoss.com...
. many other electronic products . • High-pressure cleaning as used in the manufacturing of parts for the automobile industry . 180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022...
Measurements according to EN ISO 3744: 2010 / dB(A) [L ] values are calculated . PA, 1m Measured at max pressure and rpm for a motor pump unit . 180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022...
Pressure (barg / psig) Displacement (cm / rev . ) (th) 1000 Motor speed (rpm) 5.1 PAHT C 2-6.3 typical flow curves at max pressure (measured in water) l/min l/min PAHT C 6.3 PAHT C 6.3 PAHT C 4.0 PAHT C 4.0 PAHT C 3.2...
To determine the correct motor size, both the power and torque requirement must be verified . The mechanical efficiency of the pump, at max pressure, is as follows: PAHT C 2, 3.2, 4, 6.3 0 .8 180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022...
99 . 9 8% efficient, and only allow 20 of the more noise if the VFD does not have the same 100,000 particles to pass through . right settings . 180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022...
Note: If a non-return valve is mounted in the value . inlet line, a low-pressure relief valve is also recommended between the non-return valve and the pump to protect against high-pressure peaks. System 180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022...
Always install a proper drain (12) in order to safely drain the fluid to avoid vaporization and to ensure a safe drain, without human contact before inspection and/or service . Reservoir System 180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022...
Make sure to install a proper drain to avoid any spill of fluid into the surroundings, drain the whole pump before servicing and wear neces- sary safety equipment . Read the Service Instruction before servicing the pump . 180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022...
Always install a proper drain (12) in order to safely drain the fluid to avoid vaporization and to ensure a safe drain, without human contact before inspection and/or service . Reservoir System 180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022...
Note: If a non-return valve is mounted in the value . inlet line, a low-pressure relief valve is also recommended between the non-return valve and the pump to protect against high-pressure peaks. System 180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022...
Please contact the Danfoss Sales Organiza- Pump suction line should be placed above the tion for further filter details tank bottom in order to prevent settled particles from being led into the pump . 180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022...
. Please take care to observe the recommended length tolerances of the chosen coupling, as an axial force on the pump shaft must be avoided . 180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022...
G 1⁄2 x 15 M6; Allen key 4 mm Max tighten 25 Nm 25 Nm 5 Nm torque Recommended torque values refer to steel washers containing a rubber sealing element . 180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022...
. In systems with water tank it is recommended to build in a level gauge in the tank to avoid the risk of running dry . 180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022...
Retainer plate, ball and bearing • Valve plate • Port plate 7.3 How to inspect the pump • Sealings Service manuals are available on the internet hpp .danfoss .com 180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022...
Page 41
Instruction Pump instruction PAHT C 2-6.3 180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022...
Electric Motors Motor Manual hoyermotors.com Manual 180R9230 180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022...
Page 44
The motor are balancing with half key, ensure that the drive components are also the same. Hoyer Motors, Motor Manual, October 2011 180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022...
Page 45
Data for vertically mounted motors are half of the above values. Maintenance, repairs and replacement on zone 22 motors must only be carried out by qualified specialists. Hoyer Motors, Motor Manual, October 2011 180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022...
Page 46
180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022...
Page 47
Eco design for electrical motors 2009/640/EC ATEX directive 2014/34/EU Ex II 3D Ex tc IIIB T120°C Ex II 3G Ex nA IIC T3 Year of CE marking: Signed by: Thomas Klausen July 2016 Date 180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022...
PAHT C 2 Ex PAHT C 3 .2 PAHT C 3 .2 Ex PAHT C 4 PAHT C 4 Ex PAHT C 6 .3 PAHT C 6 .3 Ex 180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022...
Guide line | Trouble shooting guide for PAH, PAHT, PAHT C , PAHT G, PAHT 674 and PAH F pumps Trouble shooting fish bone chart 180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022...
Guide line | Trouble shooting guide for PAH, PAHT, PAHT C , PAHT G, PAHT 674 and PAH F pumps No flow/no pressure Cause Remedy Comments 1.1 Dry running If no water comes out of the pump: Mount a low pressure switch in front of the (no water supply to the pump) pump and check its set point/ function .
Guide line | Trouble shooting guide for PAH, PAHT, PAHT C , PAHT G, PAHT 674 and PAH F pumps Reduced flow/reduced pressure Cause Remedy Comments 2.1 Wear on pump 2 . 1 . 1 Dismantle the pump .
Guide line | Trouble shooting guide for PAH, PAHT, PAHT C , PAHT G, PAHT 674 and PAH F pumps High torque on electric motor Cause Remedy Comments 3.1 Too high outlet pressure from pump 3 . 1 . 1 Check for blocked nozzles or a faulty Pressure changes due to flow restrictions .
Guide line | Trouble shooting guide for PAH, PAHT, PAHT C , PAHT G, PAHT 674 and PAH F pumps Noise from pump Cause Remedy Comments 4.1 Air in fluid 4 . 1 . 1 Ensure that the entire inlet line is bled Small air bubbles will accumulate and create before starting up the system .
Guide line | Trouble shooting guide for PAH, PAHT, PAHT C , PAHT G, PAHT 674 and PAH F pumps Noise from installation Cause Remedy Comments 5.1 Inlet/outlet connections (hoses/pipes) 5 . 1 . 1 Use flexible hoses at inlet/outlet connec- Non-flexible connections mounted directly on tions .
Guide line | Trouble shooting guide for PAH, PAHT, PAHT C , PAHT G, PAHT 674 and PAH F pumps Typical signs of wear 6.1 Valve plate Picture 1 A normally worn valve plate has no marks/scratches but only a slightly polished surface .
Guide line | Trouble shooting guide for PAH, PAHT, PAHT C , PAHT G, PAHT 674 and PAH F pumps 6.2 Port plate Picture 1 If the port plate has scratches, level differences or both between the arrows, the port plate must be replaced .
Page 67
Guide line | Trouble shooting guide for PAH, PAHT, PAHT C , PAHT G, PAHT 674 and PAH F pumps 180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022...
MAKING MODERN LIVING POSSIBLE Service guide. Right and wrong Right and wrong Trouble shooting guide for water Trouble shooting guide for water hydraulic systems hydraulic systems danfoss.high-pressurepumps.com hpp.danfoss.com...