Adjust the set forming dimension diameter upwards
(+) or downwards (-) by 0.1 mm or with a figure
value. Direct input via input field possible as an al-
ternative.
Only if automatic opening is active
: Upon form-
ing, the crimping dies remain on the workpiece until
the machine opens them again (holding time).
Manual opening during the holding time is possible
at any time by pressing the
button.
Holding time = time interval in which the plastic
forming of the material is completed.
Note, for PFC only:
In order that the pressure is maintained and the
crimping dies open automatically after the holding
time, the
button must remain activated for the
entire holding time. If the
button is released
before the end of the holding time, the pressure will
not be maintained, the crimping dies remain in their
position and can only be opened manually by acti-
vating the
button.
Enter the crimping die diameter into the control.
(Option) Crimping die thickness
The symbol with the input field will only be dis-
played, if the use of special crimping dies is possi-
ble in the machine, and if the selected crimping di-
mension exceeds or is equal to the smallest
possible special criming die.
(Only PFM and PFC) Data recordspecific customer
setting: Pressure top limit not to be exceeded.
(Only PFM and PFC) Data recordspecific customer
setting: Pressure bottom limit to be achieved as a
minimum in order to achieve a correct forming.
Switches from closing to forming when the diameter
of the pre-set unit is achieved.
See below, "Set machine switch point"
Switches from closing to forming when the pressure
of the pre-set unit is achieved.
See below, "Set machine switch point"