8.3
Auto Trigger
When auto trigger is enabled, the scanner automatically detects an object in front and starts reading it.
8.3.1
Normal Auto Trigger
There are two modes for auto trigger.
● Presentation auto trigger mode
This mode is meant for applications where the scanner is fixed and codes are presented.
● Handheld auto trigger mode
This mode is meant for applications where the module is not fixed.
Item
Auto trigger
Auto trigger Mode
8.3.2
Auto Trigger Sensitivity
The detection sensitivity can be adjusted. The sensitivity varies with the ambient environment and
adjustment may be necessary.
Item
Auto trigger sensitivity
8.3.3
Double read reset time
This allows setting of time interval before the same code can be decoded again in auto trigger mode.
When a code with different data is read, this will be reset.
Item
Double read reset
time
*When 0 second is set, the same code will not be decoded.
L-46X User's Manual
1st
Command
+F
Disable presentation auto trigger
+I
Enable presentation auto trigger
[DL5
Presentation auto trigger mode
[DL6
Hand held auto trigger mode
Command
[XMF
Sensitive
[XMH
Normal
[XMJ
Insensitive
Command
[D3R
Qa
Qb
Qc
Description
Description
Description
Double read reset time
Qd
(1000a+100b+10c+d) [ms]
Chapter-8
Read Options
Default
Default
Default
(valid range)
700 ms
(0-9999)
102