Please read this manual carefully before installing or using the product. Serial Number A serial number appears on all Opticon products. This official registration number is directly related to the device purchased. Do not remove the serial number from your Opticon device. Removing the serial number voids the warranty.
・Do not swing the product around by the cable. It may cause injury or damage to the device. Cable handling ・Do not wrap L-46X cable around a host device (PC, tablet etc.). It may cause breakage to the strain relief and the cable jacket, and could cause malfunction, overheating, smoke and fire.
Page 4
( 1 ) this device may not cause harmful Interference, and ( 2 ) this device must accept any interference received, including interference that may cause undesired operation. VCCI クラス B この装置は、クラスB情報技術装置です。この装置は、家庭環境で使用することを目的としていますが、 この装置がラジオやテレビジョン受信機に近接して使用されると、受信障害を引き起こすことがあります。 取扱説明書に従って正しい取り扱いをして下さい。 VCCI-B Disclaimer: OPTOELECTRONICS CO.,LTD. will not bear any responsibility in case of malfunction, accident, repair and damage assurance. L-46X User's Manual...
Page 5
Revision History Document Name : L-46X User's Manual Edition Date Page Section Description of Changes 2019/03/06 Initial release L-46X User's Manual...
Chapter-1 Abstract 1 Abstract This document provides the user’s manual for the L-46X 2D handy scanner (hereafter called “scanner”) 1.1 Feature of the Scanner 1.2 Flow to Integrate L-46X User's Manual...
The L-46X is a handheld, imager based, 2D barcode scanner that enables high speed scanning of 1D (linear) and 2D barcode as well as OCR fonts. The main features of the L-46X are as follows: ● 360° high speed reading The extremely high performance decoder and optics used in this product ensures stress-free scanning and fast response without being affected by hand movement and poor lighting conditions.
Code Options ● → (Refer to 7) String Options ● → (Refer to 8) Read Options 4. Create Setting Menu Create a 2D menu code suitable for operation. ● → (Refer to 3.1.2) 2D menu code Integrate L-46X User's Manual...
Following explains the items required before using. 2.1 Model Details 2.2 Package Contents 2.3 Detailed View 2.4 Connect to the Host 2.5 How to Read 2.6 Reading Range 2.7 Operation Transition 2.8 Buzzer and Status LED 2.9 Cable Desorption method 2.10 Optional Accessories L-46X User's Manual...
Chapter-2 Before Using Model Details The L-46X model is constructed by a combination of following. Model Cable Optional Optional Focus Vibrator Housing Interface name length AC adapter Stand None (20) -USB None None -BLK +STD L-46X None (20) None -WHT...
Following items are packed to this product. Please check before using. USB-HID / USB-COM Interface Model Following are included to USB interface model. L-46X Scanner with cable L-46X Quick Start Guide (1 copy) RS-232C Interface Model Following are packed to RS-232C interface model. L-46X Scanner with Cable...
Buzzer Orifice covered, the buzzer sound will be diminished. The sound varies depending on the settings. Buzzer settings are configurable for volume and duration. Cable Removing To remove cable, turn this stopper and pull out cable. Stopper L-46X User's Manual...
Name Open Shield Connected to pin 4 (not connected) D-sub 9pin female Open Connected to pin 6 (NC) (not connected) Case Shield *RS-232C interface has AC adapter included. *9 pin power supply model are also available. L-46X User's Manual...
Chapter-2 Before Using How to Read L-46X has “handheld” witch starts reading by pressing trigger switch, and “hands-free” which reads target code by placing it in front of the scanner. Details are described as follows. 2.5.1 Handheld The scanner read target code by acquiring the image. Reading starts by triggering, with green aiming as a guide, normally reads around 50 mm from the front edge of scanner.
*Refer to 8.1.3 for the setting to read only center of LED aiming. • Appropriate LED aiming *If the code including quiet zone is within the view angle, 360° rotation reading is possible. • Not appropriate LED aiming L-46X User's Manual...
When no detection continues for 5 seconds (default setting) while in the auto Auto trigger sleep trigger mode, scanner shift to auto trigger sleep which detects with the warm white LED turned off. Operation current transition (USB-HID) Status Typ. Unit Reading Auto trigger standby Standby L-46X User's Manual...
USB bus shift to active status Event: Pull trigger, reading success, receipt command (*When scanner is set to remote wake up) USB bus USB suspend mode Active (*When scanner is set to suspend mode) USB bus shift to non- active status L-46X User's Manual...
* Low: around 1000 Hz, Low middle: around 1000-2000 Hz, Middle low: around 2500 Hz, Middle: around 3000 Hz, Middle high: around 3500 Hz, High: around 4000Hz. * Refer to 4. Indicator for setting detail. * Above is the definition of the representative status and does not indicate all of the operations. L-46X User's Manual...
Case removing stopper Cable Unit Rotate the case removing stopper for counterclockwise Pull out the case removing stopper from grip end. 90°. Step3 With the case removing stopper removed from the grip end, carefully pull out the cable. L-46X User's Manual...
Confirm the connector insert direction of the cable unit and case removing stopper and grip end, and insert into grip end. insert. Step3 Step4 Rotate the case removing stopper for clockwise After rotation, case removing stopper dent mark position is 90°. as above drawing. L-46X User's Manual...
Dedicated stand that supports auto trigger stand mode. Automatically shift to auto trigger mode by magnet switch. 2.10.1 Stand (STD-46) Included to scanner depend on specification. Model number STD-46 Weight Approx. 365 g Mechanical drawing Turn lock Turn lock Flexible arm Flexible arm Unit: mm L-46X User's Manual...
Chapter-2 Before Using 2.10.2 Holder (STD-4101) STD-4101 is a holder to place the scanner. Mechanical Drawing: φ7 φ4.5 For desk mounting (2 places) 2.10.3 Various Exchange Cable Various exchange cable are sold separately. L-46X User's Manual...
*2 A combination of command header <STX>(0x02) and terminator <ETX>(0x03) is also possible. Input examples: 1-digit command <ESC>Δ<CR> 2-digit command <ESC>ΔΔ<CR> 3-digit command <ESC>[ΔΔΔ<CR> Two 2 digit commands <ESC>ΔΔΔΔ<CR> 2 and 3 digits command <ESC>ΔΔ[ΔΔΔ<CR> Command can be sent via “UniversalConfig” *In UniversalConfig <ESC> is sent automatically. L-46X User's Manual...
(Separator) ← Multiple sets allowed “Any menu command” (U2 etc) “@” (Separator) “ZZ” (END menu) “@” (Separator) “OTPO_UNEM@” (Stop key) ● 2D menu code can be created at “UniversalConfig”. Print *Please contact sales offices for the tools. L-46X User's Manual...
* 1D Menu codes encode an ID consisting of two to five alphanumeric characters. 1D Menu codes are Code39 labels with modified start/stop characters and therefore the scanner will not acknowledge a 1D menu code as a normal barcode. ● Menu barcode can be created at “UniversalConfig”. Print *Please contact sales offices for the tools. L-46X User's Manual...
- The recovery signal will sound and the status LED should stop flashing. - Trigger key should now be operational and the scanner should be able to read barcodes. * During forced initialization, read data will not be output to the host device. L-46X User's Manual...
The Active Settings can be returned to the factory default settings. Set the command that corresponds to the interface being used. Item Command Interface Description Remark USB-HID Restore USB-HID to factory default settings Factory Default [C01 USB-COM Restore USB-COM to factory default settings Settings RS-232C Restore RS-232C to factory default settings L-46X User's Manual...
Menu Remark Change interface to [X.ZSU[X.ZZ2 Confirm cable USB-HID Switch to USB-COM Item Command Menu Remark Change interface to [X.Z[C01[X.ZZ2 Confirm cable USB-COM Switch to RS-232C Item Command Menu Remark Change interface to [X.ZU2[X.ZZ2 Confirm cable RS-232C L-46X User's Manual...
Auto trigger become invalid by setting this disable reading. In this setting, menu labels cannot be read, only commands via serial communication are supported. Item Command Description Default Remark [EAT Enable module reading operation Command only Enable/Disable Reading operation [EAU Disable module reading operation Command only L-46X User's Manual...
When a command requires additional numerical input, the commands below can be used. Use these in one packet together with the command that requires the numerical input. Item Command Description Remark Input in a Direct input numerical specified values format L-46X User's Manual...
Chapter-4 Indicator Options 4 Indicator Options This chapter describes the options for Buzzer and Good Read LED. 4.1 Buzzer 4.2 Status LED 4.3 Good Read Aiming 4.4 Indicator in General L-46X User's Manual...
4-digit numerical command. Frequency range normally use is 2000 to 4000 Hz. The scanner most resonance around 2750 Hz. Item Command Description Default Buzzer tone Numerical setting of 2600 Hz frequency [DF0 buzzer tone frequency (1-9999) setting (1000a+100b+10c+d)[Hz] L-46X User's Manual...
The status LED lights up after a code was successfully decoded and the data was output. This can be disabled or set for several durations. Item Command Description Default Disable indicator [XT8 Indicator duration: 100 ms Status LED Indicator duration: 200 ms Indicator duration: 400 ms Indicator duration: 800 ms L-46X User's Manual...
10b + c 00-99 x10 ms 100 ms Setting example) - Lights 2 times (After 100ms: Default) Command: [EF3Q0Q0Q2 - Set first indicator duration after reading to 500 ms Continue to above indicator frequency setting Command: [EF3Q1Q5Q0 L-46X User's Manual...
Common settings for each indicator are described below. 4.4.1 Indicator Timing The indicators can be activated after decoding a code and before or after transmitting the data. Item Command Description Default Remark soon after Before data transmission decoding Indicator timing After data transmission L-46X User's Manual...
Chapter-5 Interface 5 Interface The scanner support USB-HID, USB-COM and RS-232C interface. This chapter explains each interface in detail. 5.1 USB-HID 5.2 USB-COM 5.3 RS-232C 5.4 Common Settings L-46X User's Manual...
Set according to the keyboard language. Initial value: English (USA) Set according to reading symbol encode Initial value: not use Character code data. character code Output mode Set when outputting Chinese-character. Initial value: output as it is L-46X User's Manual...
*2. When starting transmits, send CapsLock and invert status. Use when CapsLock is always ON. Return to CapsLock status when sending is completed. *3. Control CapsLock status to display as the original string. Return to original CapsLock status when transmit is complete. L-46X User's Manual...
Windows 1250 [BAY Hungarian Windows 1250 [BPJ Turkish Windows 1254 [EF4 Russian English Windows 1251 [EF5 Russian Cyrillic Windows 1251 [BAZ Brazilian Windows 1252 [E76 Chinese Windows 1252 [E77 Korean Windows 1252 [E78 Taiwanese Windows 1252 Japanese Shift-JIS L-46X User's Manual...
• The trigger cannot be turned on until the connection between PC and Does not start reading USB is established. Please refer to above “The scanner does not even trigger key is appear in Device Manager”. turned on. L-46X User's Manual...
5.2.3 Connection Confirm USB-COM interface, confirm the connection by following procedure. For Windows 10 Install Opticon USB driver. 1. Connect the scanner to the PC. 2. Right-click "Windows icon" and select "Device Manager". 3. Open "Ports (COM & LPT)". L-46X User's Manual...
In case multi byte character is not output correctly with USB-HID, this can be solved by using WIME. Windows PC Scanner Scanner Output to focused application Output to focused application USB-COM USB - COM as character information as character information Communication Communication L-46X User's Manual...
Please refer to the tool help or manual. • Reboot the PC. • Confirm that code to be read matches to the character code of the Garbled characters communication tool. • Check the line-break setting of the communication tool. Line-break is doubled L-46X User's Manual...
"Z2" (save command in non-volatile memory) needs be used after these commands to activate and save the new configuration. Item Command Description Default Remark No handshake Busy/ready Enabled after sending “Z2” Handshaking Modem ACK/NAK ACK/NAK NO RESPONSE L-46X User's Manual...
Page 57
CTS line to be tuned on. If the CTS line is not turned on within the time specified, the data transmission will be aborted. Scanner Host System Cannot Receive Command Send Software Decode Wait to Send Wait to Buzzer Finish Send Send L-46X User's Manual...
Page 58
RTS OFF. In response, the host should turn OFF the scanner’s CTS. If, while RTS is ON, the CTS line is not ON for a certain configurable period, the scanner will terminate the transmission with an error indication of the buzzer. L-46X User's Manual...
Page 59
LabelB Read Finish Processing <ACK/NAK Flow chart> Start of transmission Transmit data Start 1 sec. timer As configured Response received Response = NAK Timer ended Response = ACK Response = DC1 ERROR Buzzer ERROR Buzzer GOOD READ Buzzer L-46X User's Manual...
Page 60
If there is no response within 100 ms then the scanner terminates transmission with the good read buzzer. <ACK/NAK No Response Flow Chart> Start of transmission Transmit data Start 100 ms. timer Response received Response = NAK Timer ended Response = ACK Response = DC1 GOOD READ Buzzer ERROR Buzzer GOOD READ Buzzer L-46X User's Manual...
Set the 5.3.5 inter-character delay according to the host PC’s processing Garbled characters speed. Confirm that code to be read matches to the character code of the communication tool. Line-break is Check the line-break setting of the communication tool. doubled L-46X User's Manual...
The following menu codes / commands are provided for the data buffer mode setting. Item Command Description Default [D80 Data buffer disable Data buffer mode [D81 Data buffer enable * * When handshaking is configured, this setting is ignored and Data Buffer Mode is disabled. L-46X User's Manual...
These settings do not affect the reading of the 1D menu codes. *Refer 9.3 Sample codes for the codes. 6.1 Setting of Readable Codes 6.2 Setting of Code Common Options 6.3 Setting of Code Specific Option 6.4 Setting of Number of Characters L-46X User's Manual...
Composite UPC • UPC-A CC-A • UPC-A CC-B • UPC-E CC-A • UPC-E CC-B *Refer to 6.2.1 for convert GS1 and read. *When composite EAN or composite UPC is enabled, EAN or UPC only cannot be read. L-46X User's Manual...
*1 PDF417, Codablock F, QR Code, Data Matrix(ECC 200), Maxi Code, MicroPDF417, Aztec Code, Composite code, Aztec Runes, Micro QR and Chinese-sensible code *2 When ‘ALL 2D codes’ is enabled, a link flag will be enabled, and UPC/EAN cannot be read. L-46X User's Manual...
* ICAO travel document can be read regardless of the image direction because the format is fixed. OCR free edit To free edit standard OCR font and read, refer to 6.2.7 OCR free edit. For advanced setting, please check the separate sheet “Data Edit Programing Manual”. L-46X User's Manual...
GS1 DataBar Composite GS1 Convert GS1 Data Matrix [X/4 Enable GS1 conversion GS1 QR Code ■ To process and output GS1 conversion data within the scanner. Our application tool “UniversalConfig” enables processing and outputting GS1 symbol data. L-46X User's Manual...
Numerical value / alphabet / symbol of up to 40 digits and 2 rows can be set. * For advanced setting, please check the separate sheet “Data Edit Programing Manual”. * Please contact to the sales offices for the items cannot set. L-46X User's Manual...
This allows you to set whether or not to transmit CD (check digit) and a leading “0”. The 13 digits transfer data format that transfer a leading “0” and CD, the format becomes compatible with JAN / EAN-13. L-46X User's Manual...
Page 75
This allows you to set whether or not to transmit CD (check digit) and a leading “0”. The 8 digits transfer data format that transfer a leading “0” and CD, the format becomes compatible with JAN / EAN-8. Convert UPC-E to UPC-A format and transfer Transfer setting to UPC-A format is possible. L-46X User's Manual...
Page 76
7 digits zero CD UPC-E , Leading zero, not transmit CD, transmission UPC-E transfer digits 7 digits UPC-E , No leading zero, not transmit CD, transfer digits 6 digits Transmit UPC-E UPC-A, E conversion Transmit as UPC-A L-46X User's Manual...
CD 1 digit Add-on 2 digits Transfer data format (EAN/JAN -13 Add-on 5 digits) Data 12 digits CD 1 digit Add-on 5 digits EAN/JAN -13 CD transfer Whether to transfer EAN/JAN-13 CD (check digit) or not is configurable. L-46X User's Manual...
Page 78
ISMN conversion will convert a leading 4 digits to “M” and outputs it in 10 digits. When ISMN conversion is disabled and ISBN conversion is enabled, EAN-13 with a leading “9790” will be converted to ISBN format. Example) ISMN conversion of EAN-13 “9790230671187”; converts it to “M230671187” and outputs it. L-46X User's Manual...
Page 79
CD 1 digit Add-on 2 digits Transfer data format (EAN/JAN-8 Add-on 5 digits) Data 7 digits CD 1 digit Add-on 5 digits EAN/JAN -8 CD transfer Whether to transfer EAN/JAN-8 CD (check digit) or not is configurable. L-46X User's Manual...
When not adapting to Italian Pharmaceutical, it will not be sent. When possible Italian Pharmaceutical: This setting convert converts Code39 data to Italian Pharmaceutical format. When not adapting to Italian Pharmaceutical, it will be send with standard Code39 etc. L-46X User's Manual...
Page 82
(Code 32) Full ASCII Code 39 if possible It. Pharmaceutical only It. Pharmaceutical if possible It. Pharm Not transmit leading A for It. Pharm Transmit leading A for It. Pharm Disable concatenation Concatenation Enable concatenation L-46X User's Manual...
Whether to transfer CD (check digit) or not is configurable. Start / Stop code transfer Whether to transfer start / stop code or not is configurable. Also, it can convert the code and transfers when transferring start / stop code. L-46X User's Manual...
Page 84
Start / Stop code: <DC1><DC2><DC3><DC4> /<DC1><DC2><DC3><DC4> Disable space insertion Space insertion Enable space insertion Enable only Codabar normal mode Enable only ABC code ABC, CX conversion Enable only CX code Enable Codabar / ABC and CX L-46X User's Manual...
Disable space check for Industrial 2 of 5 S-Code Space check Enable space check for Industrial 2 of 5 Not transmit S-Code as Interleaved 2 of 5 S-Code conversion Transmit S-Code as Interleaved 2 of 5 L-46X User's Manual...
The maximum number of character that can be concatenated at a time is 400 characters. Following are the Code 128 optional setting. Code Item Command Description Default Disable GS1-128 GS1 conversion Enable GS1-128 only Code 128 Enable GS1-128 if possible Disable concatenation Concatenation Enable concatenation L-46X User's Manual...
Code Item Command Description Default CD transmit CD transmission Not transmit CD Korean Transmit dash Postal Transmit dash Authority Not transmit dash code Upside down reading enabled Upside down reading Upside down reading disabled L-46X User's Manual...
AI “01” Data (13 digits) CD (1 digit) Transfer data format (GS1 DataBar Expanded) Data (1-74 digits) ● Setting items GS1 conversion Disable / Enable GS1 DataBar’s GS1 conversion is configurable. Refer to 6.2.1 for setting detail. L-46X User's Manual...
1D data (1-74 digits) Composite data (1-338 digits) Transfer data format (CC-C) 1D data (1-74 digits) Composite data (1-2361 digits) ● Setting item GS1 conversion Disable/enable GS1 conversion of Composite GS1 DataBar by setting. Refer to 6.2.1 for details. L-46X User's Manual...
Number of code words for error correction is fixed by the symbol and cannot (MicroPDF417) be changed. Transfer data format Data (variable length) ● Setting item MicroPDF417, default is invalid. To enable the setting, refer to 6.1.5. L-46X User's Manual...
● Setting item GS1 conversion Disable/enable GS1 QR code conversion by setting. Refer to 6.2.1 for setting detail. ECI protocol output Enable/disable output of QR code ECI protocol data by setting. Refer to 6.2.6 for setting detail. L-46X User's Manual...
Page 93
Version M4: 17 x 17 module – Reed Solomon error correction 3 steps (L, M, Q) Negative barcode, Negative and mirror printed QR code are readable mirror printing Transfer data format Data (variable length) ● Setting item None in particular L-46X User's Manual...
● Setting item GS1 conversion Disable/enable GS1 Data Matrix conversion by setting. Refer to 6.2.1 for setting detail. ECI protocol output Enable/disable output of Data Matrix ECI protocol data by setting. Refer to 6.2.6 for setting detail. L-46X User's Manual...
The selectable error correction level is 5% to 95% of the data area. Transfer data format Data (variable length) ● Setting item ECI protocol output Enable/disable output of Aztec Code ECI protocol data by setting. Refer to 6.2.6 for setting detail. L-46X User's Manual...
Clear minimum length for Interleaved 2 of 5 <Esc>[DB4<CR> Set maximum length for Code39 to 12 digits <Esc>[DA1Q1Q2<CR> Clear max length for Code39 <Esc>[DA1<CR> Set max length for PDF417 to 20 digits and QR code 125 digits <Esc>[DALQ2Q0[DAJQ1Q2Q5<CR> L-46X User's Manual...
Chapter-7 String Options 7 String Options This chapter describes the alterations which can be made to the transmitted data string. The configurations available are: 7.1 Case Conversion 7.2 Prefix / Suffix L-46X User's Manual...
Convert to lower case abcd Exchange case aBcD Upper case and Lower case can be set from following commands. Items Command Description Default No case conversion Convert to upper case Case Conversion Convert to lower case Exchange case L-46X User's Manual...
Prefix Suffix (*1) Preamble Postamble for each code for each code Decoded Data Max 8 digits Max 4 digits Max 4 digits Max 8 digits *By default, <CR> is added to suffix with all codes “RZ” command. L-46X User's Manual...
Page 101
● ASCII (Refer to 7.2.3) All 128 characters ● Code identification The code identification is transmitted in OPTICON ID, ISO15424 standard or AIM-ID. ● Code length The code length is the number of characters after the output format that is configured with options in “6.3 Setting of Code Specific Options”.
• Clearing the default suffix CR is possible by scanning the RZ menu code (Set suffix for all codes) without codes for the suffix or the PR menu code (Clear suffix). • When the number of configured prefix / suffix characters exceeds the maximum limit (4 digits), the configuration will be ignored. L-46X User's Manual...
Tri-optic Codabar Industrial 2 of 5 Interleaved 2 of 5 S-Code Matrix 2 of 5 Chinese Post Matrix 2 of 5 IATA MSI/Plessey Telepen UK/Plessey Code 128 GS1-128 [XMX [XOX Code 11 [BLD [BLE Korean Postal Authority L-46X User's Manual...
Page 104
Machine Readable Visas-B [DJL [DJR Official Travel Documents 1 [DJM [DJS Official Travel Documents 2 [DJN [DJT ISBN [DJO [DJU To add to preamble / postamble, use the following command. Code Preamble Command Postamble Command Preamble / Postamble L-46X User's Manual...
The code identifier is transmitted in ISO 15424 format. ]cm • ] is ASCII value, decimal 93 • c is code character • m is modifier character Example) Add “<OPTICON Code ID>” to the all codes prefix. Configuring with Command: <Esc>RY$2<CR> 7.2.5 Code Length For 1D codes the code length is transmitted as 2 digits, excluding prefix and suffix characters.
The same barcode cannot be read twice unless another barcode is read in between or when at least “Double read reset time” has past. Example: Read multiple codes sequentially with single trigger. L-46X User's Manual...
Read time infinite Read time 10 times * When auto trigger with “Y0”, read time is automatically set by the image processing. * When auto trigger read time is auto, read time can be adjusted in 8.3.4. L-46X User's Manual...
Examples of readable positions in central reading setting Examples of unreadable positions in central reading setting * When several codes are tightly packed, it is recommended to use the Trigger Repeat (See: 8.2.1) function to Improve reading performance. L-46X User's Manual...
● Read time option: When trigger key is synchronized (Default). Example) “While trigger is pressed” “Release trigger” “Output data” ● Read time option: When read time option is 1 second or more. Example) “While trigger is pressed” “Start reading by pulling trigger again” “Output data” L-46X User's Manual...
When a code with different data is read, this will be reset. Default Item Command Description (valid range) Double read reset Double read reset time 700 ms [D3R time (1000a+100b+10c+d) [ms] (0-9999) *When 0 second is set, the same code will not be decoded. L-46X User's Manual...
Ambient light is used for detection in this mode, so this mode should not be used in a dark environment. Best used in a well-lit area. Item Command Description Default [DDH Warm white illumination detection Auto trigger [DDG Green aiming detection [DDI No illumination detection L-46X User's Manual...
Green LED floodlight used for aiming can be set to enable / disable. The brightness is also configurable. Item Command Description Default [D3D Enable LED aiming LED aiming ON/OFF [D3E Disable LED aiming [DDD Brightness "High" LED aiming [DDE Brightness "Standard" brightness [DDF Brightness "Low" L-46X User's Manual...
The Universal Config utility has some support for Data Editing, but it is an advance language and may need extra support. Please contact technical support or your sales office for more information on this. L-46X User's Manual...
Chapter-9 Appendix Code ID Table Following are the Code ID to be added to the prefix / suffix. 9.1.1 Opticon Code ID prefix / suffix value Code Code ID Code Code ID UPC-A Code 11 UPC-A +2 Code 128 UPC-A +5...
Industrial 2 of 5 Aztec Interleaved 2 of 5 S-Code QR Code Matrix 2 of 5 Micro QR Code Chinese Post Maxi Code IATA PDF417 MicroPDF417 MSI/Plessey “*” are described differently depend on code type, please refer below. L-46X User's Manual...
Page 119
Interleaved 2 of 5 option AIM/ISO15424 Code ID : I* Not check CD (G0) Not check CD (G0) Transmit CD (E0) Not Transmit CD (E1) Check CD (G1) Check CD (G1) Transmit CD (E0) Not Transmit CD (E1) L-46X User's Manual...
Page 120
Check 2CDs (BLH) or Not check CD (BLF) Check auto 1 or 2CDs (BLI) Not transmit CD (BLJ) (length > 12) Transmit CD (BLK) Codablock F option AIM/ISO15424 Code ID : O* FNC1 not used FNC1 in 1st position L-46X User's Manual...
Page 121
Maxi Code option AIM/ISO15424 Code ID: U* Symbol in mode 4 of 5, Symbol in mode 4 of 5 ECI protocol implemented Symbol in mode 2 of 3, Symbol in mode 2 of 3 ECI protocol implemented L-46X User's Manual...
Chapter-9 Appendix L-46X Specification Overview L-46X specifications overview is as follows. 9.2.1 Common Specification Overview Item Specification Note CPU:ARM Cortex-A7 Core: 800 MHz LPDDR2 RAM 1G bits DDRCLK: 400 MHz Flash ROM 1G bits Flash Memory RS-232C 300 bps to 115200 bps...
Page 123
Range of output image Select top/bottom (column) and left/right (row) Resolution of output image Full,1/2, 1/4 Interface of output image RS-232C, USB-COM USB-COM (full speed) About 3 sec Resolution: Full Baud rate RS-232C About 40 sec (baud rate: 115.2 kbps) L-46X User's Manual...
Page 124
Dust and drip proof IP42 equivalent Except protruding Dimensions Approx. 105.4 × 60 × 153.4 (DWH mm) portion Weight Approx. 112 g Excluding the cable Housing color Black / White Anti-microbial ISO 22196 equivalent White model only L-46X User's Manual...
44 character 0.169mm Data Matrix 40 character 0.254mm Data Matrix 40 character Note: The depth of field is a determined while using the OPTOELECTRONICS test chart PCS 0.9, without specular reflection and at room temperature and room humidity. L-46X User's Manual...
Page 126
0.20mm Code 128 100% 0.33mm EAN/UPC 0.169mm PDF417 0.254mm 0.169mm QR Code 0.381mm 0.169mm Data Matrix 0.254mm Note: The depth of field is the typical value measured by tilting the test chart 15° from the optical axis L-46X User's Manual...
Page 127
44 character 0.084mm Data Matrix 40 character 0.254mm Data Matrix 40 character Note: The depth of field is a determined while using the OPTOELECTRONICS test chart PCS 0.9, without specular reflection and at room temperature and room humidity. L-46X User's Manual...
Chapter-9 Appendix High Resolution (UD) model reading depth of field 0.076mm(3mil) 0.127mm(5mil) Code 39 0.254mm(10mil) 0.33mm(13mil) UPC/EAN 0.084mm(3.3mil) QR Code 0.381mm(15mil) 0.084mm(3.3mil) Data Matrix 0.254mm(10mil) [Unit: mm] L-46X User's Manual...
Chapter-9 Appendix 9.2.4 Product Label Example of label attached to the scanner is shown below: 6-digit Serial Number prited here L-46X User's Manual...
Mechanical Drawing as following drawing 1800 ± 45 Unit: mm 69.0 ± 1 <AC plug for exchanging> <DC output side> The polarity of the center of DC jack is plus (+). EIAJ Electrode classification 2 (EIAJ#2) Unit: mm L-46X User's Manual...
Chapter-9 Appendix 9.3.2 Postal Code Chinese Post Matrix 2 of 5 Korean Postal authority Intelligent Mail Barcode POSTNET PLANET Japan Postal Netherland KIX Code Australian Postal UK Postal(Royal mail) 4-State Mailmark Barcode L-46X User's Manual...