The following commands are provided for the setting ACK/NAK timeout.
Item
ACK/NAK timeout
E)
ACK/NAK No Response
The difference from the ACK/NAK mode is that when no response from the host is received within
100ms, the scanner assumes that the data has been received correctly by the host.
Response: "ACK" (ASCII:0x06)
The scanner terminates transmission with the good-read buzzer.
Response: "NAK" (ASCII:0x15)
The scanner sends the data again.
Response: "DC1" (ASCII:0x11)
The scanner terminates transmission without a good-read or error buzzer.
Timeout
If there is no response within 100 ms then the scanner terminates transmission with the good read
buzzer.
<ACK/NAK No Response Flow Chart>
Start of transmission
Transmit data
Start 100 ms. timer
Response received
No
No
Timer ended
Yes
GOOD READ Buzzer
L-46X User's Manual
1st
Command
[XI4
ACK/NAK timeout Indefinitely
[XI5
ACK/NAK timeout 100 ms
[XI6
ACK/NAK timeout 500 ms
[XI7
ACK/NAK timeout 1 s
Yes
Response = NAK
No
Response = ACK
No
Response = DC1
No
ERROR Buzzer
END