4.5.5.3. Scanner Diagnostics

Shading Test
Diagnostics > Scanner Diagnostics > Shading Test
Purpose
Operation Procedure
4-41
To check quality of scanned images, especially defect in optical devices, including lens,
mirror, lamp, and etc, are suspected.
To check quality problem as shown below
[For Platen Unit]
Press "Shade and Print report" to see if the current shading value is correct.
Mono, red, green, blue gray shading values will be shown on the printed report.
When the previous shading value is needed, press "Print Last Shade Report".
[For ADF(DSDF) Unit]
1) Load the shading sheet on the DSDF tray.
2) Enter SVC mdoe. Select the following menu.
(Diagnostics > Scanner Diagnostics > Shading Test > Shade and Print Report(ADF) )
(When the previous shading value is needed, press "Print Last Shade Report(ADF)". )
3) Check if RESULTS on the sheet is OK.
NOTE
When executing DSDF shading, use only enclosed sheet in accessory package.
Shading Test for ADF Unit must be carried out, after replacing the DSDF unit or main board.