Back Panel Connectors - TC Electronic UpCon Manual

Table of Contents

Advertisement

Resetting Ethernet communication
It may be necessary to reset Ethernet communi-
cation between UpCon and a computer during
operation. To do so, proceed as follows:
During operation, insert a straightened paper
clip or a similar object into the "Reset" hole
on the front panel until it touches the button
behind the panel, and press the button for
approximately 5 seconds until the LEDs start
blinking.
This will reset Ethernet communication with-
out interrupting audio streams.
UpCon English Manual (2014-10-07)

Back panel connectors

Fig. 16.: UpCon back panel
connectors (SDI version)
UpConstatus indicators and ports
PSU (2 x)
UpCon has two C13 type power inlet sockets.
The dual power inlets provide extended opera-
tional security and stability. They accept 100 to
230 Volts AC at 50/60 Hz.
If possible, connect these two power sockets to
two independent power sources to minimize the
risk of power loss.
Due to the redundant design, UpCon will still be
fully operational when one of the two power sup-
plies fails. However, to ensure maximum security
and stability, you should address the issue and
investigate the cause of the error indication at
the first given opportunity.
In case of complete power loss, the device is
hardware-bypassed via relays, ensuring that no
signal loss occurs.