in a reference sync error situation. In this sit-
uation, the input signals are also turned off,
and accordingly, meter activity will cease.
With both settings, UpCon will revert to the ref-
erence input signal (as set with the Sync source
parameter) once it becomes available again. The
changeover will be handled as smoothly as pos-
sible on both audio and clock.
Bypass button
Settings: Enabled, Disabled
Use the Bypass button to immediately activate a
hardware bypass of the SDI signal, allowing it to
pass through UpCon unprocessed.
UpCon English Manual (2014-10-07)

Setting up audio dithering

To set up audio dithering, go to Frame / Sys-
tem / I/O / Dither.
Fig. 28.: System – I/O – Dither page
Use the Dither page to set up if and how audio
signals should be dithered.
Setting up audio and syncing
Dither out parameters
Setting "Off" (no dithering applied),
24 bit, 20 bit, 18 bit , 16 bit
Use the Dither out parameters to configure dith-
ering for each pair of audio signals.
By default, the Dither Out parameters swill be
shown for channel pairs 1/2, 3/4, 5/6, and 7/8.
Please note that channel pairs from 9/10 to 15/16
are only available as Sync Sources when you
have the optional AES 16ch license. For more
information, see "Extending your product's ca-
pabilities with optional licenses" on page 100.
!
If you are handling data-reduced formats, be
sure to set these parameters to "Off".
55