Access the Maintenance console through an SSH connection

NOTE: Hewlett Packard Enterprise recommends the use of these tools for accessing the Maintenance console through an SSH
connection:
PuTTY
MTPuTTY
Procedure
1. Invoke one of the recommended tools on your local computer.
2. Access the appliance by specifying its fully qualified domain name or its IP address.
3. Enter the user name maintenance at the login prompt.
4. Log into the Maintenance console.

Log in to the appliance maintenance console

When you access the appliance console, you are presented with either a login screen or the appliance maintenance console
main menu:
Procedure
1. Access through the appliance console presents the appliance maintenance console main menu immediately.
After you enter your first command and before it runs, the login screen is presented.
NOTE: The Reset password option requires a challenge/response authorization.
2. Access through SSH presents the login screen immediately.
3. Enter the user name and password of a local Infrastructure administrator account on this appliance.
NOTE: You cannot log in using an Infrastructure administrator account that is authenticated by an authentication directory
service.
The appliance maintenance console login remains valid for one hour. After one hour of inactivity, you must reenter the
password. The appliance maintenance console session closes after 24 hours of inactivity.

Resetting the HPE Synergy appliance to original factory settings

About factory reset

A factory reset restores the appliance module to the original factory settings. It does not change the installed firmware version.
Use the factory reset operation for either of these reasons:
To decommission the appliance module so that you can migrate the hardware.
When decommissioning the appliance module, perform the factory reset without preserving the network settings and logs.
If the HPE Synergy appliance module is not highly available, you must reset the frame link module from the front panel