WARNING: The appliance module contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline
battery pack. A risk of fire and burns exists if the battery pack is not properly handled. To reduce the risk of personal
injury:
Do not attempt to recharge the battery.
Do not expose the battery to temperatures higher than 60°C (140°F).
Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
Replace only with the spare designated for this product.
Before you perform this procedure:
Make sure you have a T-10 Torx screwdriver available.
Create and download a backup of the appliance module. For more information, see "Creating and downloading an
appliance module backup."
Prepare a USB flash drive with the currently installed image of the appliance module. For more information, see "Preparing
a USB flash drive for reimaging an appliance module."
Create and download a support dump. For more information, see "Create a support dump file from the appliance
maintenance console."
Procedure
1. Perform either of the following:
Remove the Synergy Composer from the frame.
Remove the Synergy Image Streamer from the frame.
2. Remove the access panel.
3. Remove the battery by pressing the wire latch so that the battery pops out of the holder.
4. To replace the battery, press the new battery into the holder until the spring is engaged.
5. Install the access panel.