Powering up the appliance module

If the appliance module is removed and reinserted, it will power up automatically.
To restart or reset the appliance module manually, perform one of the following steps:
If you have a multi-enclosure setup and the appliance module you want to power up is in the remote enclosure, use the
applicator to press the pinhole button (below the Power LED) for 10 seconds or less.
If you use Composer (1st gen), the pinhole button is located inside of the Power LED.
If you do not have a multi-enclosure setup and the appliance module you want to power up is not in the remote enclosure,
power it on through the user interface. For more information, see "Powering on the appliance through the user
interface."
Powering on the appliance module through the user interface
Prerequisites
Required privileges: Infrastructure administrator, Server administrator, or Hardware Setup
Procedure
1. From the main menu, select Enclosures.
2. In the master pane, select the frame that contains the appliance module you want to power on.
3. Select the Composable Infrastructure Appliances view.
4. Click the Power on link in the Power field.
The Power field displays On after the appliance module is powered on.

Powering down the appliance module

Powering down the appliance module from the user interface enables you to log out users and cancel ongoing tasks.
Use one of the following steps:
For HPE Synergy Composer:
1. From the main menu, select Settings > Appliance.
2. Select Actions > Shut down.
This will power down both appliances in a high-availability cluster. To power down just one of the appliance modules, or if
the appliance module is in a standalone configuration, select the Shutdown option from the appliance maintenance
console of the appliance module to be serviced.
For HPE Synergy Image Streamer, from the main menu of the Image Streamer interface, select Deployment Appliances >
Actions > Shutdown. This will power down both appliance modules in a high-availability cluster. To power down just one
of the appliance modules, or if the appliance module is in a standalone configuration, select the Shutdown option from the
appliance maintenance console of the appliance module to be serviced.
NOTE: If your configuration includes both HPE Synergy Composer and HPE Synergy Image Streamer, you must perform the
shutdown action twice, one each for HPE Synergy Composer and HPE Synergy Image Streamer.