4�1�2�2� Measurement procedure
1.
After the sensors have been mounted and their
mounting position has been checked with the
Sensormate app, perform 3 dry cycles (without
injection), only closing and opening the press. This
procedure allows the sensors to stabilize and adapt
to the surface where they are mounted.
Dry cycle: consists of closing the press completely
and opening it afterwards, without any intermediate
step. The term "dry" derives from Injection mol-
ding, where this step is performed without injecting
plastics in the mold.
2.
Open the press
3.
Navigate to the Bending Measurement
under Applications > Bending.
By default, sensors 1.1, 1.2, 2.1 and 2.2 are selec-
ted. Configure the page to match the real place-
ment of the chosen sensors.
By tapping a sensor, a context menu opens. To ch-
ange the sensor, select the Change sensor
button, swipe through the available sensors, and
select the desired one.
32 / 56
During the tie-bar strain measurement, the machine must
not be operated or closed at high speeds as vibrations
can affect the measurement� Drive the machine slowly�