gefran 40B 48 User Manual

gefran 40B 48 User Manual

Position, force and pressure indicator-interceptor with input for strain-gauge and potentiometer

Advertisement

Quick Links

1 • INSTALLATION

• Dimensions and cut-out: Panel mounting

63
48
48
99
10
108
96
48
44,5
105
10
Panel mounting:
Fix the device with the bracket provided before making any electrical connections.
To mount two or more devices side by side, use the cut-out dimensions shown above.
CE MARKING: EMC (electromagnetic compatibility) conformity to EEC Directive
89/336/CEE with reference to the generic Standard EN50082-2 (immunity in industrial
environments) and EN50081-1 (emission in residential environments). BT (low voltage)
conformity to Directive 73/23/CEE as modified by Directive 93/68.
MAINTENANCE: Repairs must be done out only by trained and specialized personnel.
Cut power to the device before accessing internal parts.
Do not clean the case with hydrocarbon-based solvents (Petrol, Trichlorethylene, etc.).
Use of these solvents can reduce the mechanical reliability of the device. Use a cloth
dampened in ethyl alcohol or water to clean the external plastic case.
SERVICE: GEFRAN has a service department. The warranty excludes defects caused
by any use not conforming to these instructions.
81651C_MHW_40B48-96_0308_ENG
40B 48 / 40B 96
POSITION, FORCE and PRESSURE INDICATOR-INTERCEPTOR
with INPUT for STRAIN-GAUGE and POTENTIOMETER
70
70
45
45
115
70
92
!
For correct and safe
installation, follow the
instructions and observe
the warnings contained
in this manual.
USER'S MANUAL
SOFTWARE VERSION 1.0x / 2.0x
code 81651C / edition 09 - 03/08
2 • TECHNICAL SPECIFICATIONS
Display
Keys
Accuracy
Resolution
Main input
Linear scale ranges
Alarms (set points)
Alarm masking
Relay contact
Logic output
Triac output
(option, only for 96 format)
Fault settings
Analog retransmission (option)
Logic input
Logic input functions
Transmitter / Sensor Power Supply
Power supply (switching)
Fuse (inside device, not
operator serviceable)
Faceplate protection
Working / Storage temperatures
Relative humidity

Installation

Weight
EMC conformity has been tested with the following connections
FUNCTION
Input
Power supply cable
Relay output cables
3, 4 digit red LED's
mod. 48 digit height 10mm (4 digits)
mod. 96 digit height 20mm (3 digits),
digit height 14mm (4 digits)
3 mechanical keys (Raise, Lower, F)
0.2% f.s. at 25°C ambient temperature, ts=120msec
function of settable sample time
>13-bit, s.t. 120 msec. with probe power supply control
>12-bit, s.t. 30 msec.
(60msec with probe power supply control)
>11-bit, s.t. 15 msec.
(30msec with probe power supply control)
Differential input:
- from strain-gauge 350Ω (for pressure, force, etc.),
sensitivity 5mV/V with strain-gauge max power
15V, (7.5mV/V with max power 10V - 15mV/V with
max power 5V), positive or symmetrical
polarization, calibration with automatic calibration
of sensitivity, interrupted probe power signal
- from potentiometer with 1.2V ≥ 100 Ω power
supply
-1999 to 9999 (with 4 digit display)
-999 to 999 (with 3 digit display - only for model 96)
Configurable decimal point position, possible 32
segment linearization
Maximum of three configurable alarms:
absolute, deviation, symmetrical deviation.
Adjustable hysteresis
ability to:
- exclude on power-up
- latch reset from key and/or external contact
- insert delay filter (DON, DBI, DOF, DPO)
- set minimum intervention time
NO (NC) 5A, 250V
11Vdc, Rout = 220Ω (6V/20mA)
20...240Vac ±10%, 3A max
Snubberless, inductive and resistive load (I
2
Alarm states can be configured in probe fault
condition
4 to 20mA, max. 150 Ω load
Ri = 5,6KΩ (24V, 4mA), 1500V isolation
configurable for alarm memory reset, hold, flash,
zero, selection of max., min. peak value, peak-peak
1.2 Vdc for potentiometer > 100 Ω
5 Vdc, 10 Vdc max. 120mA, (for strain-gauge)
15 Vdc, 24 Vdc max. 50mA, (for transmitter)
40B 48 (std) 100...240Vac ±10%, 8VA
(optional) 20...27Vac/dc ±10%, 8VA
40B 96 (std) 100...240Vac/dc ±10%, 10,5VA
(optional) 11...27Vac/dc ±10%, 8VA
100 to 240Vac/dc - type T - 500mA - 250V
11 to 27Vac/dc - type T - 1.25A - 250V
IP65
0 to 50°C / -20 to 70°C
20 to 85%, non-condensing
Panel mounting, extractable from front
160g (mod. 48); 320g (mod. 96) for the complete version
CABLE
LENGTH USED
1 mm
2
3 m
1 mm
2
1 m
1 mm
2
3,5 m
t = 128A
2
s)
1

Advertisement

Table of Contents
loading

Summary of Contents for gefran 40B 48

  • Page 1 FUNCTION CABLE LENGTH USED SERVICE: GEFRAN has a service department. The warranty excludes defects caused Input 1 mm by any use not conforming to these instructions. Power supply cable...
  • Page 2 3 • DESCRIPTION OF FACEPLATE Indication of output states: OUT 1 (Alarm 1); OUT 2 (Alarm 2); PV display: Indication of process variable •• Indication of ‘HI’ or ‘Lo’ out of range OUT 3 (Alarm 3) •• Indication of open circuit (br) or short circuit (Er) ••...
  • Page 3 Device structure: identification of boards POWER SUPPLY BOARD N.B. : you can keep the OUT1 relay energized at POWER SUPPLY DISPLAY BOARD BOARD power-up by inserting jumper S2 and removing resistance R20. S1 = Status of Out 3 relay CPU BOARD A = Direct B = Inverse CPU BOARD...
  • Page 4 • POTENTIOMETER / STRAIN-GAUGE input parameters d. i. - t. u. - t. d. Select function of None digital input Zero Hold Flash Input settings Max. peak display Raise key function Min. peak display (active only in Delta peak display P.V.selection) Peak memory reset Zero + peak memory reset...
  • Page 5 • Protection Value Displayed Modifiable Protection code parameters parameters o.1, o.2, o.3 o.1, o.2, o.3 o.1, o.2 o.1, o.2 none +4 to disable In and Ou pages +8 to disable Cf page +16 to enable maintenance of reset memory at shutdown +32 base configuration (the following parameters will not be displayed: In: Ft, Fd, Of, L_L, H_L Ou: On [forced to no.
  • Page 6 • Eb Function The standard device is produced with parameter C.I.= 8, with sampling time of 120 msec and Eb function disabled. The Eb function lets you detect if the probe power supply is interrupted. This function is valid for probe currents > 20mA (8mA in version 2.0x) Example: - probe voltage 10V...
  • Page 7 • Filter - outputs with reference to parameters F.0 and r.A The diagrams refer to a normal absolute alarm with hysteresis H = 0 F.0 = 1 F.0 = 2 DON = Delayed activation DBI = Delay in turning on output after output is turned off Alarm Alarm...
  • Page 8 VAC. Resistors must be at least 2W); fit a 1N4007 diode in parallel with the coil of inductive loads that operate in DC. GEFRAN spa will not be held liable for any injury to persons and/or damage to property deriving from tampering, from any incorrect or erroneous use, or from any use not conforming to the device specifications.

This manual is also suitable for:

40b 96

Table of Contents