gefran SENSORMATE QE2008-W SET User Manual page 29

System for strain measurement with bluetooth transmission, ideal for tie bar analysis
Table of Contents

Advertisement

- The sensors must be positioned parallel to the tie bar!
- All the sensors must be evenly distributed around the tie bar 90° apart from
each other and at the same position!
- Mount the sensors when there is no load applied (e�g� no force applied on the
object / mold open)
By operating the machine in a slow and controlled manner, ensure that
- the sensors do not obstruct the normal operation of the machine�
- the integrity of the sensors is not compromised�
Mounting check via the Sensormate app - 4 Sensors on the Tie Bar
Once the installation of the sensors is complete, check if the mounting was correctly done using the Sensormate app.
1.
Open the app and scan for nearby devices. Once
the QE2008-W Set is detected, connect to it and
wait for the status of the network to be "online".
Navigate to the Bending Measurement
2.
under Applications > Bending. A cross-section of
a tie bar with 4 sensors mounted is presented.
By default, sensors 1.1, 1.2, 2.1 and 2.2 are selec-
ted. Configure the page to match the real place-
ment of the chosen sensors.
By tapping a sensor, a context menu opens. To ch-
ange the sensor, select the Change sensor
button, swipe through the available sensors, and
select the desired one.
page
swap_hor
Subject to technical modifications
29 / 56