4.
While the mounting viewer is open, the function
LEDs of the selected sensors will indicate their
relative alignment status. LEDs are
the sensors are not correctly aligned and they are
GREEN
when they are correctly aligned.
In case of incorrect alignment, unmount the
non-correctly aligned sensor and, hovering it
around the tie bar, find the position where the LEDs
become GREEN. This indicates the correct angular
position (90°) where to mount the sensor.
5.
Mount the sensor at the previosly found position.
Check that the LEDs are
ting. If they are not, repeat this step until you find
the correct spot.
6.
Tap "Exit" to return to the Bending page.
RED
when
GREEN
after the moun-
Always tilt the sensors and place
them from the long edge when
mounting
Never drag the sensors through
the surface when the magnets
are pulling� This can cause dama-
ge to the sensing element�
Subject to technical modifications
31 / 56