5.
Close the press. The sensors will continue sending
the measured strain to the app durign the whole
process.
Check if the Unbalance indicator and one tie bar
6.
are highlighted in blue.
A highlighted tie bar indicates that the tie bar strain
value is out of the set tolerance. This means that
the highlited tie bar is subject to a lower or higher
force compared to the other tie bars.
If no tie bar is highlighted, the machine is working
within the configured tolerance and the closing
force is said to be evenly distributed.
7.
If desired, press the
to a force unit (
,
set the tie bar diameter, required for the force cal-
culations.
The Total force applied on the tie bars is shown. If
working on an Injection Molding machine, this is the
Clamping force.
save_alt
8.
Press the Save
button to store the measured
data in a CSV file.
9.
To measure the dynamic distribution of the forces
over time, navigate to the Clamping Chart
page.
button to change the units
,
,