Maintenance, Cleaning, and Storage

If G-Bolt fails inspection in any way, immediately remove it from service, and contact Guardian to
inquire about its return or repair. Field serviceability testing is not required, and should not be done by the
end user.
Cleaning after use is important for maintaining the safety and longevity of G-Bolt. Remove all dirt,
corrosives, and contaminants from G-Bolt before and after each use. If G-Bolt cannot be cleaned
with plain water, use mild soap and water, then rinse and wipe dry. NEVER clean G-Bolt with corrosive
substances.
When not in use, store equipment where it will not be affected by heat, light, excessive moisture, chemicals,
or other degrading elements.

Inspection

Prior to EACH use, inspect G-Bolt for deficiencies, including, but not limited to, corrosion, deformation,
pits, burrs, rough surfaces, sharp edges, cracking, rust, paint buildup, excessive heating, alteration, and
missing or illegible labels. IMMEDIATELY remove G-Bolt from service if defects or damage are found, or
if exposed to forces of fall arrest.
Ensure that applicable work area is free of all damage, including, but not limited to, debris, rot, rust, decay,
cracking, and hazardous materials. Ensure that selected work area will support the application-specific
minimum loads set forth in this instruction manual. Work area MUST be stable.
At least every 12 months, a Competent Person other than the user must inspect G-Bolt. Competent
Person inspections MUST be recorded in inspection log in instruction manual and on equipment
inspection grid label. The Competent Person must sign their initials in the box corresponding to the
month and year the inspection took place.
During inspection, consider all applications and hazards G-Bolt have been subjected to.

Inspection Log

Date of First Use: __________________.
Product lifetime is indefinite, as long as product passes all inspection requirements. User must inspect
prior to EACH use. Competent Person other than user must complete formal inspection at least every 12
months. Competent Person to inspect and initial.
This inspection log must be specific to one G-Bolt. Separate inspection logs must be used for
each G-Bolt. All inspection records must be made visible and available to all users at all times.
If equipment fails inspection IMMEDIATELY REMOVE FROM SERVICE.