Installation And Use; Maintenance, Cleaning, And Storage - Guardian Fall Protection Diablo Cable SRL Instruction Manual

Table of Contents

Advertisement

Installation and Use

Guardian Fall Protection Diablo Cable SRLs MUST NEVER be used in Leading Edge (LE) applications.
No free fall is allowed.
ALWAYS avoid lifeline contact with sharp or abrasive edges and surfaces.
1. All PFAS components must be selected and deemed compatible with Diablo Cable SRL by Competent
Person.
2. Ensure structure to which Diablo Cable SRL is to be attached, and on which work is to be performed, is
free of all hazards, including, but not limited to, debris, rot, rust, sharp or abrasive edges and surfaces, and
hazardous materials.
3. Eliminate or minimize all risk of swing fall hazards.
4. Attach Diablo Cable SRL housing to compatible anchorage connector, and connect snap hook to applicable
D-ring on full-body harness.
5. Ensure 100% tie-off will be maintained at all times, which may require the use of a back-up or
supplementary fall protection system.

Maintenance, Cleaning, and Storage

If Diablo Cable SRL fails inspection in any way, immediately remove it from service and contact Guardian.
Cleaning after use is important for maintaining the safety and longevity of Diablo Cable SRL. Remove all
dirt, corrosives, and contaminants from Diablo Cable SRL before and after each use. If Diablo Cable SRL
cannot be cleaned with plain water, use mild soap and water, then rinse and wipe dry. NEVER clean Diablo
Cable SRL with corrosive substances.
When not in use, store equipment where it will not be affected by heat, light, excessive moisture, chemicals,
or other degrading elements.