Maintenance, Cleaning, And Storage; Inspection; Inspection Log - Guardian Fall Protection GR11 Web SRL Instruction Manual

Table of Contents

Advertisement

Maintenance, Cleaning, and Storage

If GR11 Web SRL fails inspection in any way, immediately remove it from service, and contact Guardian to
inquire about its return or repair.
Cleaning after use is important for maintaining the safety and longevity of GR11 Web SRL. Remove all dirt,
corrosives, and contaminants from GR11 Web SRL before and after each use. If GR11 Web SRL cannot be
cleaned with plain water, use mild soap and water, then rinse and wipe dry. NEVER clean GR11 Web SRL with
corrosive substances.
When not in use, store equipment where it will not be affected by heat, light, excessive moisture, chemicals,
or other degrading elements.

Inspection

Prior to EACH use, inspect GR11 Web SRL for deficiencies, including, but not limited to, corrosion, deformation,
pits, burrs, rough surfaces, sharp edges, cracking, rust, paint buildup, excessive heating, alteration, and
missing or illegible labels. IMMEDIATELY remove GR11 Web SRL from service if defects or damage are found, or
if exposed to forces of fall arrest.
Ensure that applicable work area is free of all damage, including, but not limited to, debris, rot, rust, decay,
cracking, and hazardous materials. Ensure that selected work area will support the application-specific
minimum loads set forth in this instruction manual. Work area MUST be stable.
At least every 12 months, a Competent Person other than the user must inspect GR11 Web SRL. Competent
Person inspections MUST be recorded in inspection log in instruction manual and on equipment
inspection grid label. The Competent Person must sign their initials in the box corresponding to the
month and year the inspection took place.
During inspection, consider all applications and hazards GR11 Web SRL has been subjected to.

Inspection Log

Date of First Use: __________________.
Product lifetime is indefinite, as long as it passes all pre-use and Competent Person inspections. User
must inspect prior to EACH use. Competent Person other than user must complete formal inspection at
least every 12 months. Competent Person to inspect and initial.
This inspection log must be specific to one GR11 Web SRL. Separate inspection logs must be used for
each GR11 Web SRL. All inspection records must be made visible and available to all users at all times.
If equipment fails inspection IMMEDIATELY REMOVE FROM SERVICE.
5