Modbus Communication
4.3 Parameter Assignment/Addressing
Name
Manual ID
PFD1
None
PFD2
None
PFD3
None
PFD4
None
Drive Losses
2161
Excessive Reactive
2162
Current
Speed Droop Percent 2163
Sync Motor Field Ref 2164
Avail Reactive Cur‐
2653
rent
Drive Efficiency
2168
Ids Ref Current
2276
40
Unit
Scaling
None
None
None
None
None
None
None
None
%
/ 100
&
/ 100
&
/ 100
&
/ 100
%
/ 100
%
/ 100
%
/ 100
16-bit Data Type Notes
None
Refer to appendix Parameter
Read / Write
None
Refer to appendix Parameter
Read / Write
None
Refer to appendix Parameter
Read / Write
None
Refer to appendix Parameter
Read / Write
Unsigned
Unsigned
Unsigned
Unsigned
Unsigned
Unsigned
Unsigned
Function Manual, AA, A5E50226719