Contact Siemens customer service for EDS files.
Note
Each device on the DeviceNet™ network must have an EDS file.
The EDS file provides:
• an option for more than 136 bytes of input and output
However, the drive only uses up to 136 bytes of input and output.
If the configuration tool cannot accommodate 136 bytes, you can modify the I/O Size, until the
correct quantity of input and output bytes is selected.
Note
To communicate with the drive, you must configure the DeviceNet™ controller to match the
same quantity of bytes that are set by parameter 'Network 1 I/O Size' (9951) or 'Network 2 I/O
Size' (9952).
NXGPro+ Communication Manual
Function Manual, AA, A5E50226719
all relevant data associated with a specific device for use by the configuration tool.
DeviceNet Communication
8.5 Planning/Configuring