Section 6
Lubrication System
ground the ignition module to stop the engine. On
NOTE: Make sure the oil level is checked before each
Installation
Figure 6-9.
Figure 6-9. Oil Sentry™ Location.
6.4
Testing the Switch
Compressed air, a pressure regulator, pressure gauge
Pressure Switch
Adapter for
Oil Cooler or
Oil Filter
1. Apply
adapter. See Figure 6-9.
1. Connect the continuity tester across the blade
0 psi
should indicate continuity (switch closed).
pressure increases through the range of
3.0/5.0 psi, the tester should indicate a change to
no continuity (switch open)
remain open as the pressure is increased to 90 psi
maximum.
3. Gradually decrease the pressure through the
range of 3.0/5.0 psi. The tester should indicate a
change to continuity (switch closed) down to
0 psi.
®
®