Page 28
Cross
ENUM
Difference
Output
Correlation
ENUM
Factor Output
Noise Level
ENUM
Output
Heading
ENUM
Output
Pitch Roll
ENUM
Output
Abs Tilt Output ENUM
Max Tilt
ENUM
Output
Tilt Direction
ENUM
Output
Std Dev
ENUM
Heading
Output
Std Dev Tilt
ENUM
output
Temperature
ENUM
Output
Charge
ENUM
Voltage
Output
Memory Used
ENUM
Output
July 2019 – TD 304 OPERATING MANUAL – Doppler Current Profiler Sensor
Enables cross difference output for all cells.
Doppler shift measured by the transducers on same axis, for each
depth the speed in beam 1 - speed beam 3 + speed beam 2 – speed
1
beam 4 should be close to 0.
'Off' or 'Output' (in AiCaP Off, Storage or Output+Storage).
Enables correlation factor output (only in Broadband).
1
'Off' or 'Output' (in AiCaP Off, Storage or Output+Storage).
Enables output of noise measurements from the four beams. This is a
way to check for disturbance from other acoustic devices or input noise
1
on the cable.
5)
'Off' or 'Output' (in AiCaP Off, Storage or Output+Storage).
Enables output of the compass heading.
1
'Off' or 'Output' (in AiCaP Off, Storage or Output+Storage).
Enables output of pitch and roll rotation angles (deg.).
1
'Off' or 'Output' (in AiCaP Off, Storage or Output+Storage).
Enables output of the absolute tilt. This is the angle between the sensor
plane and the horizontal plane (Deg.).
1
'Off' or 'Output' (in AiCaP Off, Storage or Output+Storage).
Enables the output of the maximum absolute tilt measured (Deg.)
during the recording interval.
1
'Off' or 'Output' (in AiCaP Off, Storage or Output+Storage).
Enables the output of the tilt direction of the sensor (Deg.M).
1
'Off' or 'Output' (in AiCaP Off, Storage or Output+Storage).
Enables standard deviation on heading output. The sensor does one
heading measurement for each ping. This is the standard deviation of
1
all the heading measurements during a recording interval.
'Off' or 'Output' (in AiCaP Off, Storage or Output+Storage).
Enables standard deviation on tilt output. The sensor does a tilt
measurement for each ping. This is the standard deviation of all the
1
absolute tilt measurements during the recording interval.
'Off' or 'Output' (in AiCaP Off, Storage or Output+Storage).
Enables the output of Temperature from Temperature sensor 4080 in
(Deg.C).Only available if the optional Temperature sensor 4080 is
1
included and calibrated from factory.
'Off' or 'Output' (in AiCaP Off, Storage or Output+Storage).
Enables output of the charge voltage to the acoustic Tx circuits. This is
a way to see if there is something wrong with the charge electronics or
1
the transducers.
5)
'Off' or 'Output' (in AiCaP Off, Storage or Output+Storage).
Enables output of the used heap memory.
1
'Off' or 'Output' (in AiCaP Off, Storage or Output+Storage).
Difference between
5)
5)
5)
5)
5)
5)
5)
SC
5)
5)
5)
No /
Low