Avalon Model Determination

Stoves & Inserts
Model, Vintage, Ser. #
700 B-Vent (Gas Stove)
1993
1001-2077
700 B-Vent (Gas Stove)
1994
2078- 4968
700 B-Vent (Gas Stove)
1997
6001 - Present
700 Direct Vent
1996
50002-Present

Avanti Model Determination

Stoves & Inserts
Model, Vintage, Ser. #
Avanti B-Vent
1995
2503-4050
Avanti B-Vent
1996
4052-Present
Avanti Direct Vent
1995
1004-3037
Avanti Direct Vent
1996
32002-Present
Avanti DVS Insert & Fireplace
Travis Industries
Introduction
Burner
Description
B-vent unit, insert or free standing on legs or pedestal. Two
Phase 1
burner orifices attach to a brass manifold attached to the valve.
93 BV
31,000 BTU
B-vent unit, insert or freestanding on legs or pedestal. Single
Phase 1
burner orifice attaches to a brass manifold attached to valve.
94 BV
31,000 BTU
B-vent unit, insert or freestanding on legs or pedestal. Burner is
Phase 2
40,000 BTU (dvm burner) with flex tube leading from right side of
96 BVM
valve to one orifice.
logshelf.
40,000 BTU
out. There is a raised platform across the front of the burner for
the front log to sit on. A natural gas burner is standard with
parts included to convert to LP. Burner orifice attaches to a
manifold penetrating the burner assembly which attaches to a
flex tube that runs to a fitting attached to the valve. Ser. Nos
6001 to 6120 use 96 burners with inflexible pilot tube (burner
removed to convert to LP). After ser. no. 6121 use 97 burners
with flexible pilot tube (LP conversion done without removing
burner).
Direct vent unit with flex tube attached to right side of the valve
Phase 2
leading to one orifice and the mixing tube located under the rear
96 DVM
log support. Has thermocouple for 30 second drop-out. There is
a raised "platform" across front of burner for front log to sit on. A
38,500 BTU
natural gas burner is standard with parts included to convert to
LP. Ser. Nos 50002 to 51227 use 96 burners with inflexible pilot
tube (burner removed to convert to LP). After ser. no. 51227 use
97 burners with flexible pilot tube (LP conversion done without
removing burner).
Burner
Description
B-vent contemporary style, bay window unit, insert or free
Phase 1
standing. Burner orifice connects directly to gas control valve.
95 BV
Burner is a single thickness sheet metal plate with small upright
flanges near left & right sides at the front to locate the front log.
31,000 BTU
Lift-off gold door is standard.
B-vent contemporary style, bay window unit, insert or free
Phase 2
standing burner has a raised "platform" for front log to sit on.
96 BVM
Has thermo-couple for 30 second dropout. Natural gas burner
standard, includes parts to convert to LP. Burner orifice
40,000 BTU
attaches to a manifold penetrating the burner assembly which
attaches to a flex tube that runs to a fitting attached to the valve.
Ser. Nos 4052 to 5537 use 96 burners with inflexible pilot tube
(burner removed to convert to LP). After ser. no. 5537 use 97
burners with flexible pilot tube (LP conversion done without
removing burner). Lift-off gold door is standard from ser. Nos
4052 to 5730. Starting with ser. No. 5731 the swing-open door
is standard.
Direct vent, contemporary style, bay window unit - freestanding
Phase 2
only.
97 DVS
platform for the front log to rest on. Has two tall flanges toward
back to stop the front log.
(modified)
leading to one orifice and mixing tube located under the rear log
31,000 BTU
support. Natural gas burner standard, includes parts to convert
to LP. Burner orifice attaches to a manifold penetrating the
burner assembly which attaches to a flex tube that runs to a
fitting attached to the valve. Burner must be removed from
stove to make gas conversion. Has lift-off gold door standard.
Direct vent, contemporary style, bay window unit, insert or free-
Phase 2
standing. Burner has raised "platform" across front of burner for
96 DVM
front log to sit on.
Burner orifice attaches to a manifold penetrating the burner
38,500 BTU
assembly which attaches to a flex tube that runs to a fitting
attached to the valve. Natural gas burner is standard with unit.
Includes parts to convert to LP. Ser. Nos 32002 to 32986 use
96 burners with inflexible pilot tube (burner removed to convert
to LP). After ser. no. 32986 use 97 burners with flexible pilot
tube (LP conversion done without removing burner). Starting
with ser. no. 33189 the swing open door is standard.
BTU dvm burner.
Phase 2
97 DVS
31,000 BTU
Gas T-Shoot Guide
Mixing tube is located under the rear
Pilot assembly has thermocouple for 30 second drop-
Burner is a box assembly with no locator flanges or
Has flex tube off right side of valve
Has thermocouple for 30 second drop-out.
See Travis Industries DVS Insert or
DVS
Fireplace
1 - 5
40,000
19203