Dvs Fireplace Blower Removal - Travis Industries Spirit 300 GS Service Manual

Table of Contents

Advertisement

DVS Fireplace Blower Removal

Warning
Make sure power is
disconnected to the
heater prior to
conducting service -
remove the fuse or
disable the breaker
servicing the heater.
Warning
Shut off all gas and
disconnect the gas line
from the heater.
1
Remove the faceplate of the fireplace
(see page 3-5).
2
Remove the burner pan assembly (see
page 4-2).
3
Remove the cover plate at the back of the firebox (see the illustration above).
4
Remove the heat shield behind the firebox.
5
Remove the two nuts (and washers) on the
right side of the blower.
Travis Industries
Blower Components
Remove the three
screws holding
the heat shield in
place.
Remove the two
nuts (and
washers) holding
the blower and
right side heat
shield in place.
Gas T-Shoot Guide
6
Remove the right side blower heat shield.
5 - 7
Remove the ten
screws holding
the plate in place.
19203