Omron MicroHAWK V320-F Series User Manual page 94

Autofocus multicode reader
Hide thumbs Also See for MicroHAWK V320-F Series:
Table of Contents

Advertisement

3 Controlling Operation and Data Output with Ethernet
 Additional Symbol Information That Can Be Appended
Additional
information
Symbol Iden-
tifier
Decodes per
Trigger
Configuration
Data Identifi-
er
Frame Num-
ber
Code Posi-
tion Coordi-
nates
Print Quality
(ISO/IEC
16022)
Print Quality
(Omron Mi-
croscan)
Print Quality
(ISO/IEC
15415)
Print Quality
(ISO/IEC
15416)
Print Quality
(ISO/IEC
29158)
Read Time
Read Cycle
ID
*1.
For more information on Symbol Quality Grade, please refer to Autofocus Multicode Reader MicroHAWK
V320-F/V330-F/V420-F/V430-F Series User Manual (Z432-E) – Symbol Quality Grade.
Additional Information
When Multiple Symbol Reading is enabled, the Output Order is read character string of symbol
1, additional information for symbol 1, read character string for symbol 2, additional information
for symbol 2, and so on.
3-38
Autofocus Multicode Reader MicroHAWK V320-F/V330-F/V420-F/V430-F Series User Manual for Communication Settings (Z407-E1)
Setting to adjust
(WebLink -
Advanced
Settings Menu)
I/O - Symbol Data
A (3 character) Symbol Identifier in-
Output
dicating the type of the read symbol
is put in front of its Read string.
I/O - Decodes per
Outputs the number of Good Read
Trigger Output
in Read Cycle.
I/O - Database
Outputs the Index Number of the
Identifier Output
Configuration Database used to get
a Good Read.
I/O - Output Object
Outputs the Frames number (num-
Info
ber of images) that were needed to
get a Good Read result. The output
is a 3 digit number.
I/O - Output Object
Outputs the coordinates of the four
Info
vertices of the read symbol in pix-
els.
Symbol Quality -
Outputs the DataMatrix Symbol
ISO/IEC 16022
Quality Grade defined by ISO/IEC
Parameters
16022.
Symbol Quality -
Outputs the Omron Microscan Pro-
Omron Microscan
prietary Symbol Quality Grade.
Parameters
Symbol Quality -
Outputs the Symbol Quality Grade
ISO/IEC 15415
defined by ISO/IEC 15415 for 2D
Parameters
Codes.
Symbol Quality -
Outputs the Symbol Quality Grade
ISO/IEC 15416
defined by ISO/IEC 15416 for Bar-
Parameters
code symbols.
Symbol Quality -
Outputs the Symbol Quality grade
ISO/IEC 29158
defined by ISO/IEC TR 29158 for
Parameters
2D Codes.
I/O - Read
Outputs the Read Duration time in
Duration Output
milliseconds.
I/O - Output Cycle
The Output Cycle ID number (num-
ID
ber of Reads executed) is output in
hexadecimal format.
Description
*1
*1
*1
*1
*1
Example Output
(For Read string
Output
ABCDE.) The de-
Order
limiter character is
a , <comma>.)
]dlABCDE
Put in
front of
the Read
string
ABCDE,00002
1
ABCDE,DB01
2
ABCDE,F010
3
ABCDE,
4
(0032,0040)
(0287,0056)
(0287,0279)
(0048,0271)
ABCDE,B,A,A,A
5
ABCDE,000,092,14
6
3,091,001,14.3,200,
16X16,PASS,349
ABCDE,C,A,C,C,C,
7
A,A,A
ABCDE,C,A,A,A,A,
8
A,C,A,A,A
ABCDE,C,C,A,B,C,
9
A,A,A
ABCDE,100
10
ABCDE,Cy-
11
cleID=0x8

Advertisement

Table of Contents
loading

Table of Contents