Appendices
32 bit
32 bit
32 bit
32 bit
32 bit
32 bit
32 bit
32 bit
32 bit
Output Assembly (Instance ID: 197)
The Output Assembly can send several commands to the code reader.
This assembly is used with MXL/SLC Input Assembly (ID: 102), 1 Decode Input Assembly (ID: 103), 4
Decode Input Assembly (ID: 104), N Decode Input Assembly (ID: 105).
COMMANDS
Member Description
• Commands
An explanation of commands that can be sent to the code reader.
Bit
0
1
A-26
Autofocus Multicode Reader MicroHAWK V320-F/V330-F/V420-F/V430-F Series User Manual for Communication Settings (Z407-E1)
Member Name
Auto Image Photometry Com-
plete
Output 1 Status
Output 2 Status
Output 3 Status
BufferOverflow
Reserved
Fault Code
Command Error Detected
Communication Error
Reserved
Host Port Buffer Overflow
Reserved
Counters
No Read Read Cycle Counter
Mismatch per Read Cycle
Counter
No Read Counter
Trigger Counter
Matchcode Counter
Mismatch Counter
Read Cycle Report
Capture Time
Total Decode Time
Total Read Cycle Time
Number of Decodes in Read
Cycle
Number of Decode Reports
RAW Input Data
Output Assembly Member Structure
Member Name
Run Mode
Trigger
Data Type
Bit Number
17
18
19
20
21
22 - 31
DINT
0
1
2
3
4 - 31
UDINT[6]
0 - 31
0 - 31
0 - 31
0 - 31
0 - 31
0 - 31
UINT[4]
0 - 15
0 - 15
0 - 15
0 - 7
0 - 7
Command
Data Length
Byte Offset
1 bit
1 bit
1 bit
1 bit
1 bit
10 bit
4 Byte
8
1 bit
1 bit
1 bit
1 bit
28 bit
24 byte
12
4 byte
4 byte
4 byte
4 byte
4 byte
4 byte
8 byte
36
2 byte
2 byte
2 byte
1 byte
1 byte
16 byte
44 byte
Size (Bytes)
4