Bit
17
18 - 31
- Trigger
Executes Read. The code reader recognizes this bit changing from 0 to 1 as the rising edge of the
trigger and its change from 1 to 0 as the falling edge of the trigger.
- New Master
When this bit is ON, the next Read result is registered as the Master Symbol.
- Disable Scanning
Enables / Disables Read Cycle.
0 = Read Cycle Enabled.
1 = Read Cycle Disabled. However, other commands can be executed.
- Clear Read Cycle Report and Counters
Reset the Counter area from the Small or Big Input Assembly to the Read character string area to 0.
- Unlatch Outputs
Turns OFF Parallel OUTPUT1, OUTPUT2, OUTPUT3 signals.
- External Ouput: External Output
Turns ON Parallel OUTPUT Signal.
Bit
0
1
2
3 - 31
32 bit
User Defined Tag
UserTag_1
UserTag_2
UserTag_3
UserTag_4
UserTag_5
UserTag_6
UserTag_7
UserTag_8
UserTag_9
UserTag_10
UserTag_11
UserTag_12
UserTag_13
UserTag_14
UserTag_15
UserTag_16
UserTag_17
UserTag_18
UserTag_19
UserTag_20
Autofocus Multicode Reader MicroHAWK V320-F/V330-F/V420-F/V430-F Series User Manual for Communication Settings (Z407-E1)
Unlatch Outputs
Reserved
Output 1
Output 2
Output 3
Reserved
Assembly Memory Allocation
Member Name
Data Type
DINT
Command
Signal Name
Bit Number
Data Length
4 Byte
0
1 bit
1
1 bit
2
1 bit
3
1 bit
4
1 bit
5
1 bit
6
1 bit
7
1 bit
8
1 bit
9
1 bit
10
1 bit
11
1 bit
12
1 bit
13
1 bit
14
1 bit
15
1 bit
16
1 bit
17
1 bit
18
1 bit
19
1 bit