Appendices
MXL/SLC Input Assembly (Instance ID: 102) on page A-8 - Same structure as
• Error Code
MXL/SLC Input Assembly (Instance ID: 102) on page A-8 - Same structure as
• Counters
MXL/SLC Input Assembly (Instance ID: 102) on page A-8 - Same structure as
• Read Cycle Report
MXL/SLC Input Assembly (Instance ID: 102) on page A-8 - Same structure as
• Decode Cycle Report
MXL/SLC Input Assembly (Instance ID: 102) on page A-8 - Same structure as
• Decode Data Length
Stores the number of characters in the Read string.
• Decode Data String
Stores the Read string. When additional information such as Print Quality Grading Standard is set, it
is stored following the Read string.
32 bit
32 bit
A-16
Autofocus Multicode Reader MicroHAWK V320-F/V330-F/V420-F/V430-F Series User Manual for Communication Settings (Z407-E1)
Assembly Memory Allocation
Member Name
InfoBits
Bit Run Mode
Bit Connection Faulted
Reserved
Reserved
Reserved
Reserved
Reserved
DeviceStatus
Run Mode
Trigger Acknowledged
Exposure Done
Decoding
Data is Ready
Read Cycle Pass
Read Cycle Fail
General Fault
Matchcode Master Label
Changed
Matchcode Enabled
Image Sensor Calibrating
Image Sensor Calibration
Complete
Training
Training Complete
Optimizing
Optimizing Complete
Auto Image Photometry Ena-
bled
Auto Image Photometry Com-
plete
Output 1 Status
Data Type
Bit Number
SINT
0
1
2
3 - 7
SINT
SINT
-
DINT
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Data Length
Byte Offset
1 Byte
0
1 bit
1 bit
1 bit
5 bit
1 Byte
1
1 Byte
2
1 byte
3
4 Byte
4
1 bit
1 bit
1 bit
1 bit
1 bit
1 bit
1 bit
1 bit
1 bit
1 bit
1 bit
1 bit
1 bit
1 bit
1 bit
1 bit
1 bit
1 bit
1 bit