3 Controlling Operation and Data Output with Ethernet
To apply this setting, click the
5
If you want to insert a fixed character string in to the read (decoded) character string to output,
select Insert your own text.
The default text in the field is /r. If you click on it, a Text input box will appear so that you can
input text from your keyboard. In the example below, ABC- is set for the 4 characters.
If you want to use a Control Character as the input, select ASCII... below the text input box.
Control characters will be displayed and can be selected from here.
When Input is complete, press Enter on the keyboard.
6
To delete the formatting you set for the output, place the cursor on it and click the X button dis-
played on the upper right.
7
Click the Done button. It will close the Output Formatting Editor screen.
How to Append Additional Symbol Information
Additional information such as print quality grade and code position coordinates can be appended to
the Read result output.
 Outputting a Code Symbol's Position Information
• WebLink - Setup - Gear Icon - Advanced Settings - I/O - Output Object Info
1
Enable Output Coordinates.
3-36
Autofocus Multicode Reader MicroHAWK V320-F/V330-F/V420-F/V430-F Series User Manual for Communication Settings (Z407-E1)