5 Controlling Operation and Data Output with RS-232C
5-1
Controlling Operation and Data Out-
put with RS-232C
This section explains how to connect the code reader to an external device (such as PLC) using
RS-232C communications and the methods that you can use to control the code reader and its output.
5-1-1
Communications Processing Flow
In a system configuration in which it is connected by Serial (RS-232C) communications to an external
device (such as PLC), serial commands can be received and code reading results can be output to the
external device.
Below is the basic flow for establishing the Serial (RS-232C) communications, executing a Read com-
mand and outputting the Read result.
External device
5-1-2
RS-232C Wiring
There are two ways of wiring the V430-F/V420-F/V320-F for RS-232C connection.
Use the Special Cable
The following cable is an example.
Refer to Autofocus Multicode Reader MicroHAWK V320-F/V330-F/V420-F/V430-F Series User
Manual (Z432-E) for details.
For V430-F
• Using the RS-232C-I/O 2 Pronge cable (V430-WQR-3M).
The D-Sub 9 Pin connector can be connected directly to an IBM PC compatible Serial Port.
V430-WQR-3M
5-2
Autofocus Multicode Reader MicroHAWK V320-F/V330-F/V420-F/V430-F Series User Manual for Communication Settings (Z407-E1)
Command
Example: Send Read command "< >" (Default)
Data
Example: Send Read result "ABCDE"
Code Reader
(Units: mm)
Need help?
Do you have a question about the MicroHAWK V320-F Series and is the answer not in the manual?