Before Use
• Pull the handle (H) to unlock.
• Grab the handle to pull the TurboFiller (E) down.
After Use
• Push the TurboFiller back in storing position, until it locks.
±
WARNING! Before releasing the lock (H), always keep a hand on the grip to avoid abrupt movement of the TurboFiller!
Rinsing of TurboFiller Hopper
The upper lever is used for rinsing the hopper, when the filling of
chemicals is completed and the lid (A) is closed.
DANGER! Do not activate this lever, unless the TurboFiller lid (A) is
closed, as spray liquid may otherwise hit the operator! Risk of
injuries and spillage on the ground.
TurboDeflector Valve
This TurboDeflector valve activates the vortex flushing of the TurboFiller.
Push the lever for liquid rotation in the hopper.
Rinsing of Chemical Containers
The valve is used for rinsing empty containers.
Enable the push-activated chemical container rinsing nozzle (B), by
lifting the lever up. Place the container over the rotating flushing nozzle
(B) in the left side of the TurboFiller. Then push to rinse the inside of the
container.