Single-Side Half Boom Wing (Option For 2-Fold Booms); Single-Side 2/3 Boom Wing (Option For 3-Fold Booms) - Hardi AEON CENTURA DELTA FORCE Instruction Book

Table of Contents

Advertisement

Single-side Half Boom Wing (Option for 2-fold booms)

It is possible to spray with only the inner wing unfolded at one of the boom wings. This function is useful when spraying
close to obstacles and in areas where a fully unfolded spray boom will not fit.
μ
ATTENTION! The single-side half boom wing system has been designed to bypass obstacles and operate in narrow
spaces, for a short duration only, and not for a continuous spray job of larger areas.
Procedure
1. Unfold the boom as explained in "Manoeuvring of the Boom (V- and Z-versions)" on page 104, and start the spray job.
2. When necessary to pass an obstacle during the spraying, stop the sprayer.
3. Lock the pendulum.
4. Fold either the left or right outer boom wing.
5. On the Grip, turn Off the spray sections placed on the outer boom wing just folded.
6. Continue spraying around the obstacle at a speed not exceeding 2 km/h.
μ
ATTENTION! Do not unlock the pendulum, when spraying with a half unfolded spray boom.
7. When the obstacle is passed, stop the sprayer.
8. Unfold the outer wing and then unlock the pendulum.
9. Turn On the closed spray sections and continue spraying at normal spraying speed.
±
WARNING! Spraying with one boom wing half unfolded, must be done at a reduced speed not exceeding 2 km/h.
Failure to do so may damage the boom!
±
WARNING! Failure to comply with the above mentioned guidelines, will damage the sprayer due to asymmetrical load
and operation with the pendulum locked.

Single-side 2/3 Boom Wing (Option for 3-fold booms)

It is possible to spray with only the inner wing and the 1st outer wing unfolded at one of the boom wings. This function is
useful when spraying close to obstacles and in areas where a fully unfolded spray boom will not fit.
μ
ATTENTION! The single-side 2/3 boom wing system has been designed to bypass obstacles and operate in narrow
spaces, for a short duration only, and not for a continuous spray job of larger areas.
Procedure
1. Unfold the boom as explained in "Manoeuvring of the Boom (V- and Z-versions)" on page 104, and start the spray job.
2. When necessary to pass an obstacle during the spraying, stop the sprayer.
3. Fold either the left or right 2nd outer boom wing.
4. If the boom slants, then compensate by adjusting the slant angle.
5. On the Grip, turn Off the spray sections placed on the 2nd outer boom wing just folded.
6. Continue spraying around the obstacle, etc.
7. When the obstacle is passed, stop the sprayer.
8. Unfold the 2nd outer wing and if necessary re-adjust the slant angle.
9. Turn On the closed spray sections and continue spraying.
±
WARNING! Failure to comply with the above mentioned guidelines, will damage the sprayer due to asymmetrical load
and operation with the pendulum locked.
5 - Operation